BlueM_icon.png BlueM.Sim | Download | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


Consumer

also refer to Theory:Consumer

File

<bluem>

  • Verbraucher (*.URB)
  • ===================
  • |------|---------------------------|------|--------------------------------------|---------------------------|
  • | | Z U S C H U S S | Ret- | V E R B R A U C H | B E D A R F |
  • | Bez. | Kng konst.Ganglinie Datei|ention| Kng Schwellenwert proz. Kennlinie | Kng konst. Ganglinie Datei|
  • |------|---------------------------|------|--------------------------------------|---------------------------|
  • | | QM JGG WGG Nr. | Std | Qswell Trenn Auft. Qzu Qab | QM JGG WGG Nr. |
  • | - | 1/2 m3/s - - - | h | 1-3 m3/s -  % m3/s m3/s | 1/2 m3/s - - - |
  • |-<-->-|-<->--<---->-<->-<->---<->-|<--->-|-<->--<---->-<--->-<--->-<----><---->-|-<->-<---->-<->-<->---<->--|
|  A   |  B      C    D   E     F  |  G   |  H     I      J     K      L     M   |  N     O    P   Q     R   | 
  • |------|---------------------------|------|--------------------------------------|---------------------------|

</bluem>

Explanations

  • A: unique ID (must begin with an U!)

Additional inflow from another system

  • B: Calculation type of the additional inflow (1 = mean value with an optional annual/ weekly pattern; 2 = additional inflow out of a time series/file)
  • C: mean inflow
  • D, E: number of the annual/ weekly pattern to be utilized
  • F: filenumber of the additional inflow time series to be utilized (refer to *.EXT-File)

Retention

  • G: Retention time in hours [h][1]

Consumption

  • H: Calculation type of the consumption (1 = threshold value, 2 = percentage distribution, 3 = characteristic curve)
Calculation type 1: threshold value
  • I: threshold value [m³/s]
  • J: selectivity
Calculation type 2: percentage distribution
  • K: distribution in [%]
Calculation type 3: characteristic curve
  • L: characteristic curve values of inflow [m³/s] (multiple rows possible)
  • M: characteristic curve values of outflow [m³/s] (multiple rows possible)

Demand

  • N: Calculation type of the demand (1 = mean value with optional annual/ weekly pattern; 2 = Demand out of a time series/file)
  • O: mean demand
  • P, Q: number of the annual/ weekly pattern to be utilized
  • R: filenumber of the demand time series to be utilized (refer to *.EXT-File)

Notes