URB-File

From BlueM
Jump to navigation Jump to search

BlueM_icon.png BlueM.Sim | Download | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


Consumer

also refer to Theory:Consumer

File

*Verbraucher (*.URB)
*===================
*
*|------|---------------------------|------|--------------------------------------|---------------------------|
*|      |          Z U S C H U S S  | Ret- |            V E R B R A U C H         |         B E D A R F       |
*| Bez. | Kng  konst.Ganglinie Datei|ention| Kng Schwellenwert proz.  Kennlinie   | Kng konst. Ganglinie Datei|
*|------|---------------------------|------|--------------------------------------|---------------------------|
*|      |        QM   JGG WGG   Nr. | Std  |      Qswell Trenn Auft.  Qzu    Qab  |      QM    JGG WGG   Nr.  |
*|  -   | 1/2   m3/s   -   -     -  |  h   | 1-3   m3/s    -     %    m3/s  m3/s  | 1/2  m3/s   -   -     -   |
*|-<-->-|-<->--<---->-<->-<->---<->-|<--->-|-<->--<---->-<--->-<--->-<----><---->-|-<->-<---->-<->-<->---<->--|
 |  A   |  B      C    D   E     F  |  G   |  H     I      J     K      L     M   |  N     O    P   Q     R   | 
*|------|---------------------------|------|--------------------------------------|---------------------------|

Explanations

  • A: unique ID (must begin with an U!)

Additional inflow from another system

  • B: Calculation type of the additional inflow (1 = mean value with an optional annual/ weekly pattern; 2 = additional inflow out of a time series/file)
  • C: mean inflow
  • D, E: number of the annual/ weekly pattern to be utilized
  • F: filenumber of the additional inflow time series to be utilized (refer to *.EXT-File)

Retention

  • G: Retention time in hours [h][1]

Consumption

  • H: Calculation type of the consumption (1 = threshold value, 2 = percentage distribution, 3 = characteristic curve)
Calculation type 1: threshold value
  • I: threshold value [m³/s]
  • J: selectivity
Calculation type 2: percentage distribution
  • K: distribution in [%]
Calculation type 3: characteristic curve
  • L: characteristic curve values of inflow [m³/s] (multiple rows possible)
  • M: characteristic curve values of outflow [m³/s] (multiple rows possible)

Demand

  • N: Calculation type of the demand (1 = mean value with optional annual/ weekly pattern; 2 = Demand out of a time series/file)
  • O: mean demand
  • P, Q: number of the annual/ weekly pattern to be utilized
  • R: filenumber of the demand time series to be utilized (refer to *.EXT-File)

Notes

  1. Bug 4: When exporting from TALSIM, the heading incorrectly states that the unit is days [d]