VER-File
Jump to navigation
Jump to search
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Branching points
also refer to Theory: Branching point
File
*Verzweigungen (*.VER) *===================== * *|------------|-------------------------------|--------------|-----------------------| *| Bez. Kng | N a e h e r u n g | 3 Kennlinie | Regeln und Steuern | *| | | 1 Schwellenw.| 2 proz.Aufteilg| | KTR | *| | | Qswell Trenn |(gibt nach Qab1)| Qzu Qab | ID Faktor JGG WGG TGG| *|------------|-------------------------------|--------------|-----------------------| *| - | 1-3 | m3/s - | % | m3/s m3/s | - - - - - | *|-<-->-|-<->-|-<----><---->-|-<------------>-|-<----><---->-|-<->-<---->-<->-<->-<->| *| A | B | C D | E | F G | H I J K L | | V001 | 1 | 0.03 1 | | | y01 | | V002 | 2 | | 50 | | y01 | | V003 | 3 | | | 0 0 | y01 | | | | | | 0.03 0.030 | | | | | | | 0.04 0.032 | | | | | | | 0.10 0.033 | | *|------------|-------------------------------|--------------|-----------------------|
Explanations
- A: ID of the branching point(must start with 'V'!)
- B: Calculation type of the distribution:
- 1 = threshold value with the option to define the selectivity
- 2 = percentage distribution
- 3 = characteristic curve
Calculation type 1: threshold value
- C: threshold value that defines as of which critical inflow Qkrit the 2. outflow is added
- D: the selectivity for the threshold value [1.0 – ∞]
Calculation type 2: percentage distribution
- E: Independent of the inflow a constant distribution in two outflows Qab1 und Qab2 according to a certain percentage ratio will be used. If 100% the 1. outflow will contain the entire inflow. ird der 1.[0 – 100%]
Calculation type 3: characteristic curve
- F, G: A dependency between outflow Qab1 and inflow resuling out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Qab2 is calculated as the remaining value of (inflow - Qab1).
Regulation and steering:
- H: ID of the control function, out of which the scaling factor will be derived (refer to KTR-File)
- I: additional factor(if not supplied or 0, this factor will be set to 1!)
- J, K, L: number of the annual/weekly/daily patternto be utilized
Depending on the calculation type the scaling factor is applied differently:
- (threshold value): the threshold value is scaled tiwh the factor
- (percentage distribution): the given percentage is scaled with the factor (however it will remain between 0 and 100)
- (characteristic curve): All Qab-values of the characteristic curve are scaled with the factor