VER-File

From BlueM
Jump to navigation Jump to search

BlueM_icon.png BlueM.Sim | Download | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


Branching points

also refer to Theory: Branching point

File

Versionen:

*Verzweigungen (*.VER)
*=====================
*
*|------------|-------------------------------|--------------|-----------------------|
*| Bez.   Kng |       N a e h e r u n g       | 3 Kennlinie  |  Regeln und Steuern   |
*|      |     | 1 Schwellenw.| 2 proz.Aufteilg|              | KTR                   |
*|      |     | Qswell Trenn |(gibt nach Qab1)|  Qzu    Qab  | ID  Faktor JGG WGG TGG|
*|------------|-------------------------------|--------------|-----------------------|
*|  -   | 1-3 |  m3/s   -    |       %        |  m3/s  m3/s  |  -    -     -   -   - |
*|-<-->-|-<->-|-<----><---->-|-<------------>-|-<----><---->-|-<->-<---->-<->-<->-<->|
*|   A  |  B  |   C      D   |       E        |    F     G   |  H    I     J   K   L |
 | V001 |  1  |  0.03    1   |                |              | y01                   |
 | V002 |  2  |              |      50        |              | y01                   |
 | V003 |  3  |              |                |      0     0 | y01                   |
 |      |     |              |                |   0.03 0.030 |                       |
 |      |     |              |                |   0.04 0.032 |                       |
 |      |     |              |                |   0.10 0.033 |                       |
*|------------|-------------------------------|--------------|-----------------------|

Explanations

  • A: ID of the branching point(must start with 'V'!)
  • B: Calculation type of the distribution:
    1 = threshold value with the option to define the selectivity
    2 = percentage distribution
    3 = characteristic curve

Calculation type 1: threshold value

  • C: threshold value that defines as of which critical inflow Qkrit the 2. outflow is added
  • D: the selectivity for the threshold value [1.0 – ∞]

Calculation type 2: percentage distribution

  • E: Independent of the inflow a constant distribution in two outflows Qab1 and Qab2 according to a certain percentage ratio will be used. If 100% the 1. outflow will contain the entire inflow. [0 – 100%]

Calculation type 3: characteristic curve

  • F, G: A dependency between outflow Qab1 and inflow resulting out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Qab2 is calculated as the remaining value of (inflow - Qab1).

Regulation and steering:

  • H: ID of the control function, out of which the scaling factor will be derived (refer to KTR-File)
  • I: additional factor(if not supplied or 0, this factor will be set to 1!)
  • J, K, L: number of the annual/weekly/daily pattern to be utilized

Depending on the calculation type the scaling factor is applied differently:

  1. (threshold value): the threshold value is scaled with the factor
  2. (percentage distribution): the given percentage is scaled with the factor (however it will remain between 0 and 100)
  3. (characteristic curve): All Qab-values of the characteristic curve are scaled with the factor