URB-File: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
m (category rename) |
||
(9 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Eingabedateien}} | {{Eingabedateien}} | ||
< | |||
<big>Consumer</big> | |||
''also refer to [[Verbraucher | Theory:Consumer]]'' | |||
==File== | |||
<bluem> | |||
*Verbraucher (*.URB) | |||
*=================== | |||
* | |||
*|------|---------------------------|------|--------------------------------------|---------------------------| | *|------|---------------------------|------|--------------------------------------|---------------------------| | ||
*| | Z U S C H U S S | Ret- | V E R B R A U C H | B E D A R F | | *| | Z U S C H U S S | Ret- | V E R B R A U C H | B E D A R F | | ||
*| Bez. | Kng konst.Ganglinie Datei|ention| Kng Schwellenwert proz. Kennlinie | Kng konst. Ganglinie Datei| | *| Bez. | Kng konst.Ganglinie Datei|ention| Kng Schwellenwert proz. Kennlinie | Kng konst. Ganglinie Datei| | ||
*|------|---------------------------|------|--------------------------------------|---------------------------| | *|------|---------------------------|------|--------------------------------------|---------------------------| | ||
*| | QM JGG WGG Nr. | | *| | QM JGG WGG Nr. | Std | Qswell Trenn Auft. Qzu Qab | QM JGG WGG Nr. | | ||
*| - | 1/2 m3/s - - - | | *| - | 1/2 m3/s - - - | h | 1-3 m3/s - % m3/s m3/s | 1/2 m3/s - - - | | ||
*|-<-->-|-<->--<---->-<->-<->---<->-|<--->-|-<->--<---->-<--->-<--->-<----><---->-|-<->-<---->-<->-<->---<->--| | *|-<-->-|-<->--<---->-<->-<->---<->-|<--->-|-<->--<---->-<--->-<--->-<----><---->-|-<->-<---->-<->-<->---<->--| | ||
| A | B C D E F | G | H I J K L M | N O P Q R | | | A | B C D E F | G | H I J K L M | N O P Q R | | ||
*|------|---------------------------|------|--------------------------------------|---------------------------| | *|------|---------------------------|------|--------------------------------------|---------------------------| | ||
</ | </bluem> | ||
==Explanations== | |||
*A: unique ID (must begin with an '''U'''!) | |||
<u>Additional inflow from another system</u> | |||
*B: Calculation type of the additional inflow (1 = mean value with an optional[[TSIM.JGG | annual]]/[[TSIM.WGG | weekly pattern]]; 2 = additional inflow out of a time series/file) | |||
*C: mean inflow | |||
*D, E: number of the [[TSIM.JGG | annual]]/[[TSIM.WGG | weekly pattern]] to be utilized | |||
*F: filenumber of the additional inflow time series to be utilized (refer to [[TSIM.EXT | *.EXT-File]]) | |||
<u>Retention</u> | <u>Retention</u> | ||
*G: Retention | *G: Retention time in hours [h]<ref name="bug4">Bug 4: When exporting from TALSIM, the heading incorrectly states that the unit is days [d]</ref> | ||
<u> | |||
*H: | <u>Consumption</u> | ||
*I: | *H: Calculation type of the consumption (1 = threshold value, 2 = percentage distribution, 3 = characteristic curve) | ||
*J: | :<u>Calculation type 1: threshold value</u> | ||
*K: | :*I: threshold value [m³/s] | ||
*L: | :*J: selectivity | ||
*M: | :<u>Calculation type 2: percentage distribution</u> | ||
<u> | :*K: distribution in [%] | ||
*N: | :<u>Calculation type 3: characteristic curve</u> | ||
*O: | :*L: characteristic curve values of inflow [m³/s] ''(multiple rows possible)'' | ||
*P, Q: | :*M: characteristic curve values of outflow [m³/s] ''(multiple rows possible)'' | ||
*R: | |||
<u>Demand</u> | |||
*N: Calculation type of the demand (1 = mean value with optional[[TSIM.JGG | annual]]/[[TSIM.WGG | weekly pattern]]; 2 = Demand out of a time series/file) | |||
*O: mean demand | |||
*P, Q: number of the [[TSIM.JGG | annual]]/[[TSIM.WGG | weekly pattern]] to be utilized | |||
*R: filenumber of the demand time series to be utilized (refer to [[TSIM.EXT | *.EXT-File]]) | |||
===Notes=== | |||
<references/> | |||
[[Category: | [[Category:BlueM.Sim input files]] | ||
Latest revision as of 03:14, 31 July 2021
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Consumer
also refer to Theory:Consumer
File
*Verbraucher (*.URB) *=================== * *|------|---------------------------|------|--------------------------------------|---------------------------| *| | Z U S C H U S S | Ret- | V E R B R A U C H | B E D A R F | *| Bez. | Kng konst.Ganglinie Datei|ention| Kng Schwellenwert proz. Kennlinie | Kng konst. Ganglinie Datei| *|------|---------------------------|------|--------------------------------------|---------------------------| *| | QM JGG WGG Nr. | Std | Qswell Trenn Auft. Qzu Qab | QM JGG WGG Nr. | *| - | 1/2 m3/s - - - | h | 1-3 m3/s - % m3/s m3/s | 1/2 m3/s - - - | *|-<-->-|-<->--<---->-<->-<->---<->-|<--->-|-<->--<---->-<--->-<--->-<----><---->-|-<->-<---->-<->-<->---<->--| | A | B C D E F | G | H I J K L M | N O P Q R | *|------|---------------------------|------|--------------------------------------|---------------------------|
Explanations
- A: unique ID (must begin with an U!)
Additional inflow from another system
- B: Calculation type of the additional inflow (1 = mean value with an optional annual/ weekly pattern; 2 = additional inflow out of a time series/file)
- C: mean inflow
- D, E: number of the annual/ weekly pattern to be utilized
- F: filenumber of the additional inflow time series to be utilized (refer to *.EXT-File)
Retention
- G: Retention time in hours [h][1]
Consumption
- H: Calculation type of the consumption (1 = threshold value, 2 = percentage distribution, 3 = characteristic curve)
- Calculation type 1: threshold value
- I: threshold value [m³/s]
- J: selectivity
- Calculation type 2: percentage distribution
- K: distribution in [%]
- Calculation type 3: characteristic curve
- L: characteristic curve values of inflow [m³/s] (multiple rows possible)
- M: characteristic curve values of outflow [m³/s] (multiple rows possible)
Demand
- N: Calculation type of the demand (1 = mean value with optional annual/ weekly pattern; 2 = Demand out of a time series/file)
- O: mean demand
- P, Q: number of the annual/ weekly pattern to be utilized
- R: filenumber of the demand time series to be utilized (refer to *.EXT-File)
Notes
- ↑ Bug 4: When exporting from TALSIM, the heading incorrectly states that the unit is days [d]