SYS-File
Jump to navigation
Jump to search
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
System-logic, System-structure
more information in Theory: Modelling Basics for BlueM
File
*Systemlogik (*.SYS) *=================== * *|-------------------------------|----------------|----------------|---|---| *| S y s t e m | Zulauf | Ablauf |WEL|BIL| *| Beschreibung | Nr. | 1 2 3 | 1 2 3 | | | *|<--------------------->-|-<-->-|-<-->-<-->-<-->-|-<-->-<-->-<-->-|-+-|-+-| *| A | B | C D E | F G H | I | J | K | Einzeleinleiter | E100 | | T100 | J | | Description | Beispiel Speicher | T100 | E100 | U100 S100 | J | J | Description | Verbraucher | U100 | T100 | SEND | J | J | Description | Transportstrecke | S100 | T100 | SEND | | | Description | Transportstrecke Absch | SEND | S100 U100 | ZPG | | | Description | ZIELPEGEL | ZPG | SEND | | | | Description *|-------------------------------|----------------|----------------|---|---|
Explanations
System
- A: Description of the Element
- B: Unique ID for the element (First letters are defined as follows:)
- Urban Catchment (FKA) : F
- Rural Catchment (EZG) : A
- Transport route (TRS) : S
- Storm-water overflow (RUE) : R
- Storm-water overflow basin (BEK) : B
- Single discharge point (EIN) : E
- Branching point (VER) : V
- Consumer (URB) : U
- Dam (TAL) : T
- Target water gauge (ZPG) = Z
- Control functions (KTR) : Y (will not be listed in the system-plan)
Inflow
- C: Inflow possibility 1 to the element
- D: Inflow possibility 2 to the element
- E: Inflow possibility 3 to the element
Outflow
- F: Outflow possibility 1 out of the element
- G: Outflow possibility 2 out of the element
- H: Outflow possibility 3 out of the element
Others
- I: Calculation and output of the hydrographs in a WEL-File? [J/N] J = Yes, N = No
- J: Calculation and output of the balance in a BLZ-File? [J/N]
- K: Optional Element description
BlueM.Sim-Quality
- The system element "ZIELPEGEL (ZPG)" has to be the last element in the SYS-file.
Reason: BlueM.Sim-Quality assumes an identical array identifier for both "ElemCont" and "ISYS" and the LaPipe-Array, which does not hold if the ZIELPEGEL is not at the end of the SYS-File, because it is included in the array ISYS but not in ElemCont.