KTR-File
Jump to navigation
Jump to search
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Control functions
also refer to Theory: System states
File
Including an example for the calculation of hydro-power production at a dam.
*Kontrollfunktionen (*.KTR) *========================== * *Kontrolltypen: Typ: A = Aktuelle Systemzustaende * B = Bilanzen (Abweichungen vom Sollwert) * C = Bilanzen (aktuelle Systemzustaende) * P = Pegel * *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-------------------------------| *| Bez. |KTR| Funkt.|KTR| Sys-| 1.KTR |WEL| Beschreibung | S O L L W E R T| I S T W E R T | *| an|Kng| S Z A |Typ|zust.|Z Kng Fak | | | Wert JGG | Kng |Zschr|fest.Zeitraum|Monat| *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| *| | | | | | | | | Tsd.m3 | 1-3 | max.| Start Ende | dt= | *| J/N| | J/N i | | | | | | m3/s, mm - | | 7200| tt.mm tt.mm |Monat| *|-<-->-+-|<->|-+-+-+-|-+-|-<->-|<><-><--->|-+-|-<------------------>-|-<-------->-<->-|-<->-|<--->|-++.++-++.++-|-----| *| A B | C | D E F | G | H | I J K | L | M | N O | P | Q | R S | T | | T100 J |y01| J N 0 | A | QA1 | | J | Turbine discharge | | | | | | | T100 J |y02| J N 3 | F | WSP | | J | Hydraulic head | | | | | | *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| * *Kontrollgruppen: KGRP: Z = Zusammenfassung verschiedener Kontrollfunktionen * Wert: 1 : Kontrolliert IST - Wert * 2 : Kontrolliert FAKTOR - Wert * *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-------------------------------| *| Bez. |KTR| Funkt.|KTR| Sys-| 1.KTR |WEL| Beschreibung | S O L L W E R T| I S T W E R T | *| an|Kng| S Z A |Typ|zust.|Z Kng Fak | | | Wert JGG | Kng |Zschr|fest.Zeitraum|Monat| *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| *| | | | | | | | | Tsd.m3 | 1-3 | max.| Start Ende | dt= | *| J/N| | J/N i | | | | | | m3/s, mm - | | 7200| tt.mm tt.mm |Monat| *|-<-->-+-|<->|-+-+-+-|-+-|-<->-|<><-><--->|-+-|-<------------------>-|-<-------->-<->-|-<->-|<--->|-++.++-++.++-|-----| *| A B | C | D E F | G | H | I J K | L | M | N O | P | Q | R S | T | | KGRP J |y03| J N 0 | A | |+ y01 0.85| J | Hydropower production| | | | | | | | | | | |* y02 9.81| | | | | | | | *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--|
Explanations
- Hint
- Control functions for the same element must be listed immediately one after anathoer (Bug 342)
Control functions
General
- A: ID of the element from which a system state is to be called
- B: Control function enabled/disabled? [J/N] J = Yes, N = No
- C: Unique ID of the control function(must begin with
y
!) - D: Interpolation between supporting points [J/N]
- E: Interpolation in time [J/N]
- F: function type (if control-type
F
it must be identical to the function type in the FKT-File. For other control-types it should always be 0! - G: Control-type:
A
= current stateF
= Function (in this case the function must be defined in the FKT-File!)B
= Balance with target/referenceC
= Balance without target/referenceP
= Control water gage
- H: System state ( different possibilities according to element-type, e.g.
1AB
,1ZU
. For a dam alsoVOL
,WSP
or the identification of the control/steering function) - I, J, K: only relevant for control groups
- L: Discharge wave output in a KWL-File [J/N]
- M: Description
Target-value (required only if control-type B
)
- N: Target-value [Tsd m³; m³, mm]
- O: Annual pattern of the target-value
Is-value / current value (required only if control-type B
and/or C
)
- P: ID of the calculation-type of the is-value /current value: [1-3]
- Calculation-type 1: variable, gliding time horizon
- Q: Number of time increments [max. 7200]
- Calculation-type 2: fix time horizon
- R: Beginning [TT.MM] [day.month]
- S: End [TT.MM] [day.month]
- Calculation-type 3: fix time horizon month
- T: Value is not required, is not imported
Control-groups
Refer to control-functions,however with the following differences:
- A: ID of the control-group(has to be
KGRP
!) - H: Irrelevant for control-groups
- I: Calculation rules for the combination of control-functions/groups. Possible operators are: +, -, *, /, <, >, <=, >=
- J: ID of the control-function which is to be utilized (refer to C)
- K: Multiplier for this control-function