HYA-File: Difference between revisions

From BlueM
Jump to navigation Jump to search
Mkissel (talk | contribs)
mNo edit summary
Mkissel (talk | contribs)
mNo edit summary
Line 28: Line 28:
** <code>1</code>: wide-crested
** <code>1</code>: wide-crested
** <code>2</code>: roof-shaped
** <code>2</code>: roof-shaped
** <code>3</code>: Hight/Width = 1
** <code>3</code>: Height/Width = 1
** <code>4</code>: Hight/Width < 0.4
** <code>4</code>: Height/Width < 0.4
** <code>5</code>: sharp-edged
** <code>5</code>: sharp-edged
*'''E''': Weir crest [müNN]
*'''E''': Weir crest [müNN]
*'''F''': Weir width [m]
*'''F''': Weir width [m]
*'''G''': weir coefficient [-] <code>0 < &micro; &le; 1</code>
*'''G''': weir coefficient [-] <code>0 < &micro; &le; 1</code>
*'''H''': flexible/movable weir: ID of the control-function(e.g. "<code>y02</code>"),whichs value shall be subtracted from the weir hight.(refer to [[#Hints|Hints]]).
*'''H''': flexible/movable weir: ID of the control-function(e.g. "<code>y02</code>"),whichs value shall be subtracted from the weir height.(refer to [[#Hints|Hints]]).
'''Pipe(s):''' if there are several pipes one after another the following pipe sections are to be written into the next line (without a new HYA ID)
'''Pipe(s):''' if there are several pipes one after another the following pipe sections are to be written into the next line (without a new HYA ID)
*'''I''': Heigth of the inlet edge
*'''I''': Height of the inlet edge
*'''J''': Pipe length
*'''J''': Pipe length
*'''K''': Pipe diameter
*'''K''': Pipe diameter
Line 49: Line 49:
*'''S''': Inlet height [müNN]
*'''S''': Inlet height [müNN]
*'''T''': Coefficient of losses [-] <code>0 < &eta; &lt; 1</code>
*'''T''': Coefficient of losses [-] <code>0 < &eta; &lt; 1</code>
*'''U''' & '''V''': Minimum 2 rows with supporting points for the efficeny-curve <code>&eta;<sub>T</sub>=f(Q/Q<sub>max</sub>)</code> of the turbine
*'''U''' & '''V''': Minimum 2 rows with supporting points for the efficiency-curve <code>&eta;<sub>T</sub>=f(Q/Q<sub>max</sub>)</code> of the turbine


==Hints==
==Hints==


===Tailwater level for turbines and weirs===
===Tailwater level for turbines and weirs===
A Tailwater level is supplied by a control-function (system status).The ID of the desired control-funtcion must be named in the column <code>'''WSP unten'''</code>. The IDs of the control-functions are assigned in the  [[KTR-Datei|KTR-File]].
A Tailwater level is supplied by a control-function (system status). The ID of the desired control-funtcion must be named in the column <code>'''WSP unten'''</code>. The IDs of the control-functions are assigned in the  [[KTR-Datei|KTR-File]].


If no tailwater level is supplied, the tailwaterlevel will be determined as a <code>MIN_mNN</code>, which is a constant with the value -490 müNN.
If no tailwater level is supplied, the tailwaterlevel will be determined as a <code>MIN_mNN</code>, which is a constant with the value -490 müNN.

Revision as of 02:04, 27 February 2013

BlueM_icon.png BlueM.Sim | Download | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF



Hydraulics

File

<bluem>

  • Hydraulik (*.HYA)
  • =================
  • |-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------|
  • | | | | Wehrüberfall (1) | Rohrleitung(en) (2) | Turbine (3) |
  • | HYA | WSP | Kng |Wehr- Wehr- Wehr- Fak| Einl- Länge D A- Um- kB Zeta | P Qmax Qmin Hoehe Ver- %von eta |
  • | ID |unten| |Form kante Breite mue hue| kante quer fang | Leistg lust Qmax |
  • |-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------|
  • | - |KTRID| 1-3 | 1-5 mNN m - KTR| mNN m mm m2 m mm | KW m3/s m3/s mNN -  % - |
  • |-<->-|-<->-|-<->-|-<->-<----->-<--->-<-->-<->|<---->-<---->-<--->-<--->-<--->-<--->-<--->|-<---->-<--->-<--->-<----->-<--->-<--->-<--->|
|  A  |  B  |  C  |  D     E      F     G   H |   I      J     K     L     M     N     O  |    P     Q     R      S      T     U     V  |
  • |-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------|

</bluem>

Explanations

General:

  • A: ID of the hydraulic element
  • B: ID of the control function which supplies the tailwater level (e.g. "y02")
  • C: Identifier: Calculation-type: 1: weir overflow, 2: pipe, 3: turbine

Weir overflow:

  • D: Weir form [1-5]:
    • 1: wide-crested
    • 2: roof-shaped
    • 3: Height/Width = 1
    • 4: Height/Width < 0.4
    • 5: sharp-edged
  • E: Weir crest [müNN]
  • F: Weir width [m]
  • G: weir coefficient [-] 0 < µ ≤ 1
  • H: flexible/movable weir: ID of the control-function(e.g. "y02"),whichs value shall be subtracted from the weir height.(refer to Hints).

Pipe(s): if there are several pipes one after another the following pipe sections are to be written into the next line (without a new HYA ID)

  • I: Height of the inlet edge
  • J: Pipe length
  • K: Pipe diameter
  • L: Cross-section area (if K is given, the cross-section area is not needed)
  • M: Perimeter (if K is given, the perimeter is not needed)
  • N: Roughness coefficient
  • O: Coefficient of loss (Inlet losses)

Turbine:

  • P: Turbine capacity [kW]
  • Q: Turbine absorption capacity [m³/s]
  • R: Minimum flow rate [m³/s]
  • S: Inlet height [müNN]
  • T: Coefficient of losses [-] 0 < η < 1
  • U & V: Minimum 2 rows with supporting points for the efficiency-curve ηT=f(Q/Qmax) of the turbine

Hints

Tailwater level for turbines and weirs

A Tailwater level is supplied by a control-function (system status). The ID of the desired control-funtcion must be named in the column WSP unten. The IDs of the control-functions are assigned in the KTR-File.

If no tailwater level is supplied, the tailwaterlevel will be determined as a MIN_mNN, which is a constant with the value -490 müNN.

Lowerable weir

A lowerable weir can be implemented by writing the ID of a control-function (refer to KTR-File) into the column Fak hue. The value/factor from the control-function will be subtracted from the normal weir crest for each time increment (not multiplied).