SYS-File: Difference between revisions

From BlueM
Jump to navigation Jump to search
mNo edit summary
mNo edit summary
Line 28: Line 28:
* A: Description of the Element
* A: Description of the Element
* B: Unique ID for the element ''(First letters are defined as follows:)''
* B: Unique ID for the element ''(First letters are defined as follows:)''
**Urban Catchement (FKA) : '''F'''
**Urban Catchment (FKA) : '''F'''
**Rural Catchment (EZG) : '''A'''
**Rural Catchment (EZG) : '''A'''
**Transport route (TRS) : '''S'''
**Transport route (TRS) : '''S'''
Line 37: Line 37:
**Consumer (URB) : '''U'''
**Consumer (URB) : '''U'''
**Dam (TAL) : '''T'''
**Dam (TAL) : '''T'''
**Target water gage (ZPG) = '''Z'''
**Target water gauge (ZPG) = '''Z'''
**Control funtions (KTR) : '''Y''' ''(will not be listet in the system-plan)''
**Control functions (KTR) : '''Y''' ''(will not be listed in the system-plan)''
'''Inflow'''
'''Inflow'''
* C: Inflow possibility 1 to the element
* C: Inflow possibility 1 to the element
Line 55: Line 55:


==BlueM.Sim-Quality==
==BlueM.Sim-Quality==
* The system element "ZIELPEGEL (ZPG)" has to be the '''last''' element in the SYS-file. <br /> Reason: BlueM.Sim-Quality assumes an identical array identifier for both "ElemCont" and "ISYS" and the LaPipe-Array, which does not hold if the ZIELPEGEL is not at the end of the sys-file, because it is included in the array ISYS but not in ElemCont.
* The system element "ZIELPEGEL (ZPG)" has to be the '''last''' element in the SYS-file. <br /> Reason: BlueM.Sim-Quality assumes an identical array identifier for both "ElemCont" and "ISYS" and the LaPipe-Array, which does not hold if the ZIELPEGEL is not at the end of the SYS-File, because it is included in the array ISYS but not in ElemCont.


[[Kategorie:BlueM Eingabedateien]]
[[Kategorie:BlueM Eingabedateien]]

Revision as of 01:57, 27 February 2013

BlueM_icon.png BlueM.Sim | Download | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


System-logic, System-structure

more information in Theory: Modelling Basics for BlueM

File

*Systemlogik (*.SYS)
*===================
*
*|-------------------------------|----------------|----------------|---|---|
*|       S  y  s  t  e  m        |    Zulauf      |      Ablauf    |WEL|BIL|
*|    Beschreibung        |  Nr. |  1    2    3   |  1    2    3   |   |   |
*|<--------------------->-|-<-->-|-<-->-<-->-<-->-|-<-->-<-->-<-->-|-+-|-+-|
*|            A           |   B  |   C    D    E  |   F    G    H  | I | J | K
 | Einzeleinleiter        | E100 |                | T100           | J |   | Description 
 | Beispiel Speicher      | T100 | E100           | U100 S100      | J | J | Description 
 | Verbraucher            | U100 | T100           | SEND           | J | J | Description
 | Transportstrecke       | S100 | T100           | SEND           |   |   | Description
 | Transportstrecke Absch | SEND | S100 U100      | ZPG            |   |   | Description
 | ZIELPEGEL              | ZPG  | SEND           |                |   |   | Description
*|-------------------------------|----------------|----------------|---|---|

Explanations

System

  • A: Description of the Element
  • B: Unique ID for the element (First letters are defined as follows:)
    • Urban Catchment (FKA) : F
    • Rural Catchment (EZG) : A
    • Transport route (TRS) : S
    • Storm-water overflow (RUE) : R
    • Storm-water overflow basin (BEK) : B
    • Single discharge point (EIN) : E
    • Branching point (VER) : V
    • Consumer (URB) : U
    • Dam (TAL) : T
    • Target water gauge (ZPG) = Z
    • Control functions (KTR) : Y (will not be listed in the system-plan)

Inflow

  • C: Inflow possibility 1 to the element
  • D: Inflow possibility 2 to the element
  • E: Inflow possibility 3 to the element

Outflow

  • F: Outflow possibility 1 out of the element
  • G: Outflow possibility 2 out of the element
  • H: Outflow possibility 3 out of the element

Others

  • I: Calculation and output of the hydrographs in a WEL-File? [J/N] J = Yes, N = No
  • J: Calculation and output of the balance in a BLZ-File? [J/N]
  • K: Optional Element description

BlueM.Sim-Quality

  • The system element "ZIELPEGEL (ZPG)" has to be the last element in the SYS-file.
    Reason: BlueM.Sim-Quality assumes an identical array identifier for both "ElemCont" and "ISYS" and the LaPipe-Array, which does not hold if the ZIELPEGEL is not at the end of the SYS-File, because it is included in the array ISYS but not in ElemCont.