FKT-File: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
m (wording) |
||
Line 64: | Line 64: | ||
c 'B': Kontrollfunktion - Bilanz | c 'B': Kontrollfunktion - Bilanz | ||
</fortran> | </fortran> | ||
*D: [[Funktionsarten|Function type]] (''an Asterisk <code>*</code> after the function-type | *D: [[Funktionsarten|Function type]] (''an Asterisk <code>*</code> after the function-type causes BlueM to write the function to a file with a name in the form of <code>T100QS1.FKT</code> during the simulation'') | ||
*E: Altitude | *E: Altitude | ||
*F: X-Value | *F: X-Value |
Revision as of 13:04, 25 February 2013
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Functions
File
*Funktionen (*.FKT) *================== * *|------|------------------------ FUNKTIONSWERTE -----------------------|-------------| *| Bez. | Funktion | Fkt | h X-Wert Y-Wert | Datum | *| | | Nam Art| mNN - - | TT.MM hh:mm | *|-<-->-|<------------------->|-<->---+-|-<---->-<-------->-<------>----|-++.++-++:++-| *| A | B | C D | E F G | H | *|-<-->-|<------------------->|-<->---+-|-<---->-<-------->-<------>----|-++.++-++:++-| | T100 |Verdunstung | ETP 6 | 0 0 | 01.01 00:00 | | | | | 0.005 1 | | | | | | 1 1 | | *| |<------------------->|-<->-----|-<---->-<-------->-<------>----|-++.++-++:++-| | |Hochwasserentlastung | QH1 3*| 0 0 | 01.01 00:00 | | | | | 0.8178584 0 | | | | | | 0.8289547 3.75 | | | | | | 0.85669529 27.47999 | | | | | | 0.88443589 65 | | | | | | 0.91217649 107.6999 | | | | | | 0.94154888 150.3999 | | | | | | 0.97092134 193.1 | | | | | | 1 235.8 | | *| | |-<->---+-|-<---->-<-------->-<------>----|-++.++-++:++-| | | | QH1 6 | 0 0 | 01.01 00:00 | | | | | 0.005 1 | | | | | | 1 1 | | *| |<------------------->|-<->-----|-<---->-<-------->-<------>----|-++.++-++:++-| | |Hochwasserschutzraum | QS1 2*| 0 0 | 01.01 00:00 | | | | | 0.67099637 5 | | | | | | 1 5 | | *| | | |-<---->-<-------->-<------>----|-++.++-++:++-| | | | | 0 0 | 01.06 00:00 | | | | | 0.7362684 5 | | | | | | 1 5 | | *| | | |-<---->-<-------->-<------>----|-++.++-++:++-| | | | | 0 0 | 31.12 00:00 | | | | | 0.67099637 5 | | | | | | 1 5 | | *| | |-<->---+-|-<---->-<-------->-<------>----|-++.++-++:++-| | | | QS1 6 | 0 0 | 01.01 00:00 | | | | | 0.005 1 | | | | | | 1 1 | | *|------|---------------------|---------|-------------------------------|-------------|
Explanations
- A: ID of the element belonging to / corresponding to the function
- B: Description of the function
- C: Unique ID for the function(for requierements regarding the first letter please visit MODFKT.FOR:)
<fortran> c Funktionstypen: Variablenname: TYP, Character*1 c 'S': Kennlinie (z.B. Speicherkennlinie Oberfl.=f(Vol)) c 'O': Speicheroberflaechenfunktion - (z.B. Niederschlag auf den Speicher) c 'K': Steuerfunktion - konstant c 'Q': Steuerfunktion - variabel c 'G': Grenzfunktion c 'A': Kontrollfunktion - Aktueller Systemzustand (Q oder Vol) c 'B': Kontrollfunktion - Bilanz </fortran>
- D: Function type (an Asterisk
*
after the function-type causes BlueM to write the function to a file with a name in the form ofT100QS1.FKT
during the simulation) - E: Altitude
- F: X-Value
- G: Y-Value
- H: Date [day.month hh:mm]