Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Hydraulics
File
*Hydraulik (*.HYA) *================= *|-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------| *| | | | Wehrüberfall (1) | Rohrleitung(en) (2) | Turbine (3) | *| HYA | WSP | Kng |Wehr- Wehr- Wehr- Fak| Einl- Länge D A- Um- kB Zeta | P Qmax Qmin Hoehe Ver- %von eta | *| ID |unten| |Form kante Breite mue hue| kante quer fang | Leistg lust Qmax | *|-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------| *| - |KTRID| 1-3 | 1-5 mNN m - KTR| mNN m mm m2 m mm | KW m3/s m3/s mNN - % - | *|-<->-|-<->-|-<->-|-<->-<----->-<--->-<-->-<->|<---->-<---->-<--->-<--->-<--->-<--->-<--->|-<---->-<--->-<--->-<----->-<--->-<--->-<--->| | A | B | C | D E F G H | I J K L M N O | P Q R S T U V | *|-----|-----|-----|---------------------------|-------------------------------------------|---------------------------------------------|
Explanations
General:
- A: ID of the hydraulic element
- B: ID of the control function which supplies the tailwater level (e.g. "
y02
") - C: Identifier: Calculation-type:
1
: weir overflow,2
: pipe,3
: turbine
Weir overflow:
- D: Weir form [1-5]:
1
: wide-crested2
: roof-shaped3
: Height/Width = 14
: Height/Width < 0.45
: sharp-edged
- E: Weir crest [müNN]
- F: Weir width [m]
- G: weir coefficient [-]
0 < µ ≤ 1
- H: flexible/movable weir: ID of the control-function(e.g. "
y02
"),whichs value shall be subtracted from the weir height.(refer to Hints).
Pipe(s): if there are several pipes one after another the following pipe sections are to be written into the next line (without a new HYA ID)
- I: Height of the inlet edge
- J: Pipe length
- K: Pipe diameter
- L: Cross-section area (if K is given, the cross-section area is not needed)
- M: Perimeter (if K is given, the perimeter is not needed)
- N: Roughness coefficient
- O: Coefficient of loss (Inlet losses)
Turbine:
- P: Turbine capacity [kW]
- Q: Turbine absorption capacity [m³/s]
- R: Minimum flow rate [m³/s]
- S: Inlet height [müNN]
- T: Coefficient of losses [-]
0 < η < 1
- U & V: Minimum 2 rows with supporting points for the efficiency-curve
ηT=f(Q/Qmax)
of the turbine
Hints
Tailwater level for turbines and weirs
A Tailwater level is supplied by a control-function (system status). The ID of the desired control-funtcion must be named in the column WSP unten
. The IDs of the control-functions are assigned in the KTR-File.
If no tailwater level is supplied, the tailwaterlevel will be determined as a MIN_mNN
, which is a constant with the value -490 müNN.
Lowerable weir
A lowerable weir can be implemented by writing the ID of a control-function (refer to KTR-File) into the column Fak hue
. The value/factor from the control-function will be subtracted from the normal weir crest for each time increment (not multiplied).