KTR-File: Difference between revisions
Jump to navigation
Jump to search
(Übersetzung) |
m (category rename) |
||
(4 intermediate revisions by one other user not shown) | |||
Line 4: | Line 4: | ||
<big>Control functions</big> | <big>Control functions</big> | ||
''also refer to [[Systemzustände| | ''also refer to [[Systemzustände|Theory: System states]]'' | ||
==File== | ==File== | ||
Including an example for the calculation of | Including an example for the calculation of hydro-power production at a dam. | ||
<bluem> | <bluem> | ||
*Kontrollfunktionen (*.KTR) | *Kontrollfunktionen (*.KTR) | ||
Line 52: | Line 52: | ||
===Control functions=== | ===Control functions=== | ||
'''General''' | '''General''' | ||
*'''A''': | *'''A''': ID of the element from which a system state is to be called | ||
*'''B''': Control | *'''B''': Control function enabled/disabled? [J/N] J = Yes, N = No | ||
*'''C''': | *'''C''': Unique ID of the control function(must begin with <code>y</code>!) | ||
*'''D''': Interpolation between supporting points [J/N] | *'''D''': Interpolation between supporting points [J/N] | ||
*'''E''': Interpolation in time [J/N] | *'''E''': Interpolation in time [J/N] | ||
*'''F''': [[Funktionsarten| | *'''F''': [[Funktionsarten|function type]] (if control-type <code>F</code> it must be identical to the function type in the [[FKT-Datei|FKT-File]]. For other control-types it should always be 0! | ||
*'''G''': Control-type: | *'''G''': Control-type: | ||
** <code>A</code> = current | ** <code>A</code> = current state | ||
** <code>F</code> = Function (in this case the function must be defined in the [[FKT-Datei]]!) | ** <code>F</code> = Function (in this case the function must be defined in the [[FKT-Datei|FKT-File]]!) | ||
** <code>B</code> = Balance with target/reference | ** <code>B</code> = Balance with target/reference | ||
** <code>C</code> = Balance without target/reference | ** <code>C</code> = Balance without target/reference | ||
** <code>P</code> = Control water gage | ** <code>P</code> = Control water gage | ||
*'''H''': System | *'''H''': System state ( different possibilities according to element-type, e.g. <code>1AB</code>, <code>1ZU</code>. For a dam also <code>VOL</code>, <code>WSP</code> or the identification of the control/steering function) | ||
*'''I, J, K''': only | *'''I, J, K''': only relevant for [[#Kontrollgruppen|control groups]] | ||
*'''L''': Discharge wave output in a [[KWL-Datei]] [J/N] | *'''L''': Discharge wave output in a [[KWL-Datei|KWL-File]] [J/N] | ||
*'''M''': Description | *'''M''': Description | ||
'''Target-value''' (required only if control-type <code>B</code>) | '''Target-value''' (required only if control-type <code>B</code>) | ||
*'''N''': Target-value [Tsd m³; m³, mm] | *'''N''': Target-value [Tsd m³; m³, mm] | ||
*'''O''': [[JGG-Datei| | *'''O''': [[JGG-Datei|Annual pattern]] of the target-value | ||
'''Is-value / current value''' (required only if control-type <code>B</code> and/or <code>C</code>) | '''Is-value / current value''' (required only if control-type <code>B</code> and/or <code>C</code>) | ||
*'''P''': | *'''P''': ID of the calculation-type of the is-value /current value: [1-3] | ||
:'''Calculation-type 1: variable, gliding time horizon | :'''Calculation-type 1: variable, gliding time horizon | ||
:*'''Q''': Number of time | :*'''Q''': Number of time steps [max. 7200] | ||
:'''Calculation-type 2: fix time horizon''' | :'''Calculation-type 2: fix time horizon''' | ||
:*'''R''': Beginning [TT.MM] [day.month] | :*'''R''': Beginning [TT.MM] [day.month] | ||
Line 82: | Line 82: | ||
===Control-groups=== | ===Control-groups=== | ||
Refer to [[#Kontrollfunktionen| | Refer to [[#Kontrollfunktionen|control-functions]],however with the following differences: | ||
*'''A''': | *'''A''': ID of the control-group(has to be <code>KGRP</code>!) | ||
*'''H''': Irrelevant for control-groups | *'''H''': Irrelevant for control-groups | ||
*'''I''': Calculation rules for the combination of control-functions/groups. Possible | *'''I''': Calculation rules for the combination of control-functions/groups. Possible operators are: +, -, *, /, <, >, <=, >= | ||
*'''J''': | *'''J''': ID of the control-function which is to be utilized (refer to '''C''') | ||
*'''K''': Multiplier for | *'''K''': Multiplier for this control-function | ||
[[ | [[Category:BlueM.Sim input files]] |
Latest revision as of 02:20, 1 August 2021
BlueM.Sim | Download | Application | Theory | Development
Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF
Control functions
also refer to Theory: System states
File
Including an example for the calculation of hydro-power production at a dam.
*Kontrollfunktionen (*.KTR) *========================== * *Kontrolltypen: Typ: A = Aktuelle Systemzustaende * B = Bilanzen (Abweichungen vom Sollwert) * C = Bilanzen (aktuelle Systemzustaende) * P = Pegel * *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-------------------------------| *| Bez. |KTR| Funkt.|KTR| Sys-| 1.KTR |WEL| Beschreibung | S O L L W E R T| I S T W E R T | *| an|Kng| S Z A |Typ|zust.|Z Kng Fak | | | Wert JGG | Kng |Zschr|fest.Zeitraum|Monat| *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| *| | | | | | | | | Tsd.m3 | 1-3 | max.| Start Ende | dt= | *| J/N| | J/N i | | | | | | m3/s, mm - | | 7200| tt.mm tt.mm |Monat| *|-<-->-+-|<->|-+-+-+-|-+-|-<->-|<><-><--->|-+-|-<------------------>-|-<-------->-<->-|-<->-|<--->|-++.++-++.++-|-----| *| A B | C | D E F | G | H | I J K | L | M | N O | P | Q | R S | T | | T100 J |y01| J N 0 | A | QA1 | | J | Turbine discharge | | | | | | | T100 J |y02| J N 3 | F | WSP | | J | Hydraulic head | | | | | | *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| * *Kontrollgruppen: KGRP: Z = Zusammenfassung verschiedener Kontrollfunktionen * Wert: 1 : Kontrolliert IST - Wert * 2 : Kontrolliert FAKTOR - Wert * *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-------------------------------| *| Bez. |KTR| Funkt.|KTR| Sys-| 1.KTR |WEL| Beschreibung | S O L L W E R T| I S T W E R T | *| an|Kng| S Z A |Typ|zust.|Z Kng Fak | | | Wert JGG | Kng |Zschr|fest.Zeitraum|Monat| *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--| *| | | | | | | | | Tsd.m3 | 1-3 | max.| Start Ende | dt= | *| J/N| | J/N i | | | | | | m3/s, mm - | | 7200| tt.mm tt.mm |Monat| *|-<-->-+-|<->|-+-+-+-|-+-|-<->-|<><-><--->|-+-|-<------------------>-|-<-------->-<->-|-<->-|<--->|-++.++-++.++-|-----| *| A B | C | D E F | G | H | I J K | L | M | N O | P | Q | R S | T | | KGRP J |y03| J N 0 | A | |+ y01 0.85| J | Hydropower production| | | | | | | | | | | |* y02 9.81| | | | | | | | *|--------|---|-------|---|-----|----------|---|----------------------|----------------|-----|--1--|------2------|--3--|
Explanations
- Hint
- Control functions for the same element must be listed immediately one after anathoer (Bug 342)
Control functions
General
- A: ID of the element from which a system state is to be called
- B: Control function enabled/disabled? [J/N] J = Yes, N = No
- C: Unique ID of the control function(must begin with
y
!) - D: Interpolation between supporting points [J/N]
- E: Interpolation in time [J/N]
- F: function type (if control-type
F
it must be identical to the function type in the FKT-File. For other control-types it should always be 0! - G: Control-type:
A
= current stateF
= Function (in this case the function must be defined in the FKT-File!)B
= Balance with target/referenceC
= Balance without target/referenceP
= Control water gage
- H: System state ( different possibilities according to element-type, e.g.
1AB
,1ZU
. For a dam alsoVOL
,WSP
or the identification of the control/steering function) - I, J, K: only relevant for control groups
- L: Discharge wave output in a KWL-File [J/N]
- M: Description
Target-value (required only if control-type B
)
- N: Target-value [Tsd m³; m³, mm]
- O: Annual pattern of the target-value
Is-value / current value (required only if control-type B
and/or C
)
- P: ID of the calculation-type of the is-value /current value: [1-3]
- Calculation-type 1: variable, gliding time horizon
- Q: Number of time steps [max. 7200]
- Calculation-type 2: fix time horizon
- R: Beginning [TT.MM] [day.month]
- S: End [TT.MM] [day.month]
- Calculation-type 3: fix time horizon month
- T: Value is not required, is not imported
Control-groups
Refer to control-functions,however with the following differences:
- A: ID of the control-group(has to be
KGRP
!) - H: Irrelevant for control-groups
- I: Calculation rules for the combination of control-functions/groups. Possible operators are: +, -, *, /, <, >, <=, >=
- J: ID of the control-function which is to be utilized (refer to C)
- K: Multiplier for this control-function