Consumers withdraw as well as discharge water. They can be interpreted as municipal or industrial water works with connecting supply grid. Consumers require potable water or water for other uses and discharge it back into a natural system (e.g. river)  through the sewer system and waste water treatment plant with a certain time delay. The time delay indicates how long in average the water remains within the consumer  before it is discharged into a natural system (e.g. river) after having been treated in the waste water treatment plant. Consumers replace a detailed simulation of an urban area and its sewer system. However if a more differentiated consideration of urban areas is needed, this can be achieved by using urban catchments, pipes and reservoirs (as retention structures within the sewer system).  
Consumers withdraw as well as discharge water. They can be interpreted as municipal or industrial water works with connecting supply grid. Consumers require potable water or water for other uses and discharge it back into a natural system (e.g. river)  through the sewer system and waste water treatment plant with a certain time delay. The time delay indicates how long in average the water remains within the consumer  before it is discharged into a natural system (e.g. river) after having been treated in the waste water treatment plant. Consumers replace a detailed simulation of an urban area and its sewer system. However if a more differentiated consideration of urban areas is needed, this can be achieved by using urban catchments, pipes and reservoirs (as retention structures within the sewer system).  
Line 20: Line 21:
'''Option 2:''' a measured or generated time series in the time series management  
'''Option 2:''' a measured or generated time series in the time series management  


==Wiedereinleitung in das System==
==Discharge back into the system==


[[Bild:Theorie_Abb46.gif|thumb|400px|Abbildung 46: Volumenströme eines Verbrauchers]]
[[Bild:Theorie_Abb46.gif|thumb|400px|Abbildung 46: Flows of a consumer]]


Genau wie ein Verbraucher Zuschuss aus Fremdgebieten beziehen kann, so kann er auch Wasser an Gebiete außerhalb des betrachteten Systems abgeben. Eine solche Situation liegt dann vor, wenn ein Wasserwerk mehrere Versorgungsgebiete bedienen muss, wobei mindestens eines nicht Bestandteil des zu simulierenden Systems ist. Das Entlastungsverhalten einer Kanalisation in ein Fremdgebiet kann über diese Methode vereinfacht abgebildet werden. Dieses Verhalten entspricht der Simulation von Überleitungen in andere Einzugsgebiete.
A consumer can't just receive additional inflow from other systems. It can discharge water into areas outside of the considered system. E.g. this would be the case if the water works are responsible for multiple supply zones and at least one of these zones is not within the system which is to be simulated. This method can be used to depict discharge characteristics of sewer systems into another area. This behavior corresponds to the simulation of connections/ transfers with/ into other catchments.


In solch einem Fall verhält sich ein Verbraucher wie ein Aufteilungsbauwerk, wobei drei verschiedene Konzepte denkbar sind (genaue Erläuterung der Optionen finden sich beim Element [[Aufteilungsbauwerke / Verzweigungen|Verzweigung]].
In these cases a consumer acts as a branching point. There are three possible concepts to represent this behaviour ( for more information please refer to [[Branching points]]).


'''Option 1:''' Schwellwertkonzept


:Überschreitet das vom Verbraucher zum System zurückfließende Wasser einen bestimmten Grenzwert, wird der über dem Grenzwert liegende Anteil abgeschlagen bzw. nicht mehr in das System zurückgeleitet.
'''Option 1:''' Threshold model


'''Option 2:''' Prozentuale Aufteilung
:If discharge from the consumer back into the system surpasses a certain threshold, the amounts above this threshold are deducted respectively not reentered into the system.


:Ein bestimmter Prozentsatz des vom Verbraucher zum System zurückfließenden Wassers wird als Abschlag in andere Einzugsgebiete behandelt und nicht mehr in das System zurückgeführt.
'''Option 2:''' Percentage distribution


'''Option 3:''' Aufteilung gemäß einer Kennlinie
: A certain percentage of the consumers discharge back into the system is deducted and is discharged into a different catchment and therefore is not reentered into the system.


:Die Höhe des Abschlags in andere Gebiete erfolgt in Abhängigkeit der aktuellen vom Verbraucher zurückfließenden Menge.


Die Volumenströme eines Verbrauchers sind in [[:Bild:Theorie_Abb46.gif|Abbildung 46]] veranschaulicht.
'''Option 3:''' Distribution according to a characteristic curve


{{HierarchieFuss}}
: The deducted amount, which is discharged into other areas, is determined in dependency on the current discharge of the consumer back into the system.
 
The flows of a consumer are depicted in [[:Bild:Theorie_Abb46.gif|Abbildung 46]] .


[[Kategorie:BlueM Theorie]]
[[Kategorie:BlueM Theorie]]

Latest revision as of 08:33, 9 January 2015

BlueM_icon.png BlueM.Sim | Downloads | Application | Theory | Development

Consumers withdraw as well as discharge water. They can be interpreted as municipal or industrial water works with connecting supply grid. Consumers require potable water or water for other uses and discharge it back into a natural system (e.g. river) through the sewer system and waste water treatment plant with a certain time delay. The time delay indicates how long in average the water remains within the consumer before it is discharged into a natural system (e.g. river) after having been treated in the waste water treatment plant. Consumers replace a detailed simulation of an urban area and its sewer system. However if a more differentiated consideration of urban areas is needed, this can be achieved by using urban catchments, pipes and reservoirs (as retention structures within the sewer system).


Demand characteristics

Demand characteristics provide information about the desired amounts of water. These amounts can be defined via two different options.

Option 1: a constant hydrograph with a daily, monthly or annual pattern.

Option 2: a measured or generated time series in the time series management

Additional inflow characteristics

A consumers water demands can be met through more than one river basin or catchment. If a consumer acquires water from outside of the considered system a additional inflow into the system occurs. The additional inflow characteristics can be defined via two different options as well.

Option 1: a constant hydrograph with a daily, monthly or annual pattern.

Option 2: a measured or generated time series in the time series management

Discharge back into the system

Abbildung 46: Flows of a consumer

A consumer can't just receive additional inflow from other systems. It can discharge water into areas outside of the considered system. E.g. this would be the case if the water works are responsible for multiple supply zones and at least one of these zones is not within the system which is to be simulated. This method can be used to depict discharge characteristics of sewer systems into another area. This behavior corresponds to the simulation of connections/ transfers with/ into other catchments.

In these cases a consumer acts as a branching point. There are three possible concepts to represent this behaviour ( for more information please refer to Branching points).


Option 1: Threshold model

If discharge from the consumer back into the system surpasses a certain threshold, the amounts above this threshold are deducted respectively not reentered into the system.

Option 2: Percentage distribution

A certain percentage of the consumers discharge back into the system is deducted and is discharged into a different catchment and therefore is not reentered into the system.


Option 3: Distribution according to a characteristic curve

The deducted amount, which is discharged into other areas, is determined in dependency on the current discharge of the consumer back into the system.

The flows of a consumer are depicted in Abbildung 46 .