INP-File
For the description of the drainage system a regular SWMM5 input file is required. The current version implemented in BlueM.MPC is SWMM 5.0.018. The following standards have to be followed in order to use SWMM5 for BlueM.MPC simulations:
- The last line in the [OPTIONS] sections demands the length of the control step in minutes.
- Time dependent controls of the actuators are induced by control rules. The section [CONTROLS] is therefore compulsory. For every control step within the control horizon a control rule is required. Every rule must begin with the line IF SIMULATION TIME > as shown in the example below.
<bluem> [TITLE]
SWMM 5.0.018b TU Darmstadt ihwb Datum: 05.11.2010
[OPTIONS] FLOW_UNITS LPS INFILTRATION CURVE_NUMBER FLOW_ROUTING DYNWAVE START_DATE 04/01/2008 START_TIME 12:00:00 REPORT_START_DATE 04/01/2008 REPORT_START_TIME 12:00:00 END_DATE 04/04/2008 END_TIME 12:00:00 SWEEP_START 01/01 SWEEP_END 12/31 DRY_DAYS 0 REPORT_STEP 00:01:00 WET_STEP 00:01:00 DRY_STEP 01:00:00 ROUTING_STEP 0:00:01 ALLOW_PONDING YES INERTIAL_DAMPING NONE VARIABLE_STEP 0.00 LENGTHENING_STEP 0 MIN_SURFAREA 0 NORMAL_FLOW_LIMITED BOTH SKIP_STEADY_STATE NO FORCE_MAIN_EQUATION D-W LINK_OFFSETS DEPTH MIN_SLOPE 0
- CONTROL_STEP 00
- 10:00
[FILES] USE INFLOWS "D:\Data\Develop\DevTest\SWMM\M180_MPC\M180Inflow.txt" USE HOTSTART "D:\Data\Develop\DevTest\SWMM\M180_MPC\M180.hsf"
- SAVE HOTSTART "D
- \Data\Develop\DevTest\SWMM\M180_MPC\M180.hsf"
. . .
[CONTROLS] RULE T5 IF SIMULATION TIME > 1:00 THEN PUMP B100Pp SETTING = 0.50
RULE T4 IF SIMULATION TIME > 0:50 THEN PUMP B100Pp SETTING = 0.50
RULE T3 IF SIMULATION TIME > 0:40 THEN PUMP B100Pp SETTING = 0.50
RULE T2 IF SIMULATION TIME > 0:30 THEN PUMP B100Pp SETTING = 0.50
RULE T1 IF SIMULATION TIME > 0:20 THEN PUMP B100Pp SETTING = 0.50
RULE T0 IF SIMULATION TIME > 0:10 THEN PUMP B100Pp SETTING = 0.50
. . .
<\bluem>