RUE-File: Difference between revisions

From BlueM
Jump to navigation Jump to search
(Übersetzung)
mNo edit summary
Line 28: Line 28:
* D: the selectivity for the threshold value
* D: the selectivity for the threshold value
'''Calculation type 2: percentage distribution'''
'''Calculation type 2: percentage distribution'''
* E: Independent of the inflow a constant distribution in two outflows Q<sub>dr</sub> and Q<sub>ent</sub> according to a certain percentage ratio will be used. If 100%  Q<sub>dr</sub> will conist of the entire inflow.
* E: Independent of the inflow a constant distribution in two outflows Q<sub>dr</sub> and Q<sub>ent</sub> according to a certain percentage ratio will be used. If 100%  Q<sub>dr</sub> will consist of the entire inflow.
'''Calculation type 3: characteristic curve'''
'''Calculation type 3: characteristic curve'''
* F, G: A dependency between outflow Q<sub>dr</sub> and inflow resulting out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Q<sub>ent</sub> is calculated as the remaining value of (inflow - Q<sub>dr</sub>). Attention: The characteristic curve is extrapolated in the calculation which results in the slope of the last interval beeing used to calculate the extrapolated outflows, if greater inflows occur than the last value of the characteristic curve.
* F, G: A dependency between outflow Q<sub>dr</sub> and inflow resulting out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Q<sub>ent</sub> is calculated as the remaining value of (inflow - Q<sub>dr</sub>). Attention: The characteristic curve is extrapolated in the calculation which results in the slope of the last interval being used to calculate the extrapolated outflows, if greater inflows occur than the last value of the characteristic curve.
'''Steering options'''
'''Steering options'''
* H: ID of the conrtol function in the Kennung [[KTR-Datei | KTR-File]] (Parameter KTRKng). The ID must begin with the letter 'y'.
* H: ID of the control function in the [[KTR-Datei | KTR-File]] (Parameter KTRKng). The ID must begin with the letter 'y'.
* I: ID of the time series,with which a time dependent scaling of the throttle outflow can be achieved (not yet implemented in the  Quellcode)
* I: ID of the time series,with which a time dependent scaling of the throttle outflow can be achieved (not yet implemented in the  Quellcode)
[[Kategorie:BlueM Eingabedateien]]
[[Kategorie:BlueM Eingabedateien]]

Revision as of 03:08, 27 February 2013

BlueM_icon.png BlueM.Sim | Downloads | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


Storm-water overflow

also refer to Theory:Branching point

File

*Regenüberläufe (*.RUE)
*=====================
*
*|------------|-------------------------------|--------------|-----|-----|
*| Bez.   Kng |       N a e h e r u n g       |  Kennlinie   | Ktr | Str |
*|      |     | Schwellenwert| proz. Aufteilg |              |     |     |
*|      |     |  Qdr   Trenn |(gibt nach Qdr) |  Qzu    Qdr  | ID  | ZR  |
*|------------|-------------------------------|--------------|-----|-----|
*|  -   | 1-3 |  l/s    -    |       %        |   l/s   l/s  |  -  |  -  |
*|-<-->-|-<->-|-<----><---->-|-<------------>-|-<----><---->-|-<->-|-<->-|
 |   A  |  B  |   C      D   |       E        |    F     G   |  H  |  I  |
*|------------|-------------------------------|--------------|-----|-----|

Explanations

  • A: Unique ID of the storm-water overflow (must begin with 'R')
  • B: Calculation type (1 = threshold value with the option to define the selectivity; 2 = percentage distribution; 3 = characteristic curve)

Calculation type 1: threshold value

  • C: threshold value that defines as of which critical inflow Qdr the 2. outflow will be added
  • D: the selectivity for the threshold value

Calculation type 2: percentage distribution

  • E: Independent of the inflow a constant distribution in two outflows Qdr and Qent according to a certain percentage ratio will be used. If 100% Qdr will consist of the entire inflow.

Calculation type 3: characteristic curve

  • F, G: A dependency between outflow Qdr and inflow resulting out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Qent is calculated as the remaining value of (inflow - Qdr). Attention: The characteristic curve is extrapolated in the calculation which results in the slope of the last interval being used to calculate the extrapolated outflows, if greater inflows occur than the last value of the characteristic curve.

Steering options

  • H: ID of the control function in the KTR-File (Parameter KTRKng). The ID must begin with the letter 'y'.
  • I: ID of the time series,with which a time dependent scaling of the throttle outflow can be achieved (not yet implemented in the Quellcode)