<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.bluemodel.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Heusch</id>
	<title>BlueM - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.bluemodel.org/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=Heusch"/>
	<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php/Special:Contributions/Heusch"/>
	<updated>2026-04-09T12:00:12Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.39.3</generator>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=System%C3%BCbergreifende_hydrologische_Methoden&amp;diff=7096</id>
		<title>Systemübergreifende hydrologische Methoden</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=System%C3%BCbergreifende_hydrologische_Methoden&amp;diff=7096"/>
		<updated>2015-01-24T10:01:51Z</updated>

		<summary type="html">&lt;p&gt;Heusch: New navigation&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{BlueM.Sim_nav}}&lt;br /&gt;
{{BlueMTheory_nav}}&lt;br /&gt;
&lt;br /&gt;
Im den folgenden Abschnitten werden modellübergreifende Methoden beschrieben, die von den verschiedenen Systemelementen verwendet werden und somit ein wesentlicher Bestandteil der Software sind.&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM Theorie]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Talsperren&amp;diff=7095</id>
		<title>Talsperren</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Talsperren&amp;diff=7095"/>
		<updated>2015-01-24T10:00:34Z</updated>

		<summary type="html">&lt;p&gt;Heusch: New navigation&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{BlueM.Sim_nav}}&lt;br /&gt;
{{BlueMTheory_nav}}&lt;br /&gt;
&lt;br /&gt;
Das Talsperrenmodul erhält seine Steuerungsanweisungen über funktionale Zusammenhänge, die zwischen den verschiedenen Nutzungen und dem Speicherinhalt und beliebigen anderen Systemzuständen definiert werden. Im Falle von Verbundsteuerungen oder korrespondierenden Kontrollquerschnitten existieren zusätzliche Steuerungsanweisungen, welche die Abgaben beeinflussen.&lt;br /&gt;
&lt;br /&gt;
Die Berechnung von Speichern ist im [[Umsetzung der Gesetzmäßigkeiten für die Simulation|Kapitel 2.3]] detailliert erklärt.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Betriebsregelkonzept==&lt;br /&gt;
&lt;br /&gt;
Zum bestmöglichen wasserwirtschaftlichen Betrieb von Speichersystemen sind Handlungsanweisungen erforderlich, die eindeutig festlegen wie bei gegebenen Systembelastungen und -zuständen Wasser gespeichert, abgegeben oder verteilt werden soll. Die Summe dieser Anweisungen wird in einem Betriebsplan zusammengefasst. Ein Betriebsplan kann sich aus vielen Einzelvorschriften zusammensetzen, z.B. die Einhaltung einer Abgabe in Abhängigkeit des Speicherinhalts. Eine Einzelvorschrift kann wiederum als Betriebsregel bezeichnet werden.&lt;br /&gt;
&lt;br /&gt;
Da die Formulierung einer Betriebsregel immer mit einem korrigierenden Eingriff in das natürliche Abflussverhalten in Verbindung steht, muss zu ihrer Ausführung die Möglichkeit zur Durchflussänderung gegeben sein. Dazu sind nur wenige wasserwirtschaftliche Elemente geeignet. Normalerweise werden diese Speicher mit regulierbaren Auslässen sein. Ansonsten stehen variable Aufteilungsbauwerke oder veränderliche Wehre zur Verfügung.&lt;br /&gt;
&lt;br /&gt;
Der Zweck aller Betriebsregeln liegt in der Anpassung wasserwirtschaftlicher [[Systemzustände]] zur Einhaltung vorgegebener Zielvorstellungen. Dabei ist es unerheblich an welchem Ort die zu regelnden Systemzustände und Zielgrößen auftreten, solange über eine Änderung an den Systemzuständen die Zielgrößen beeinflusst werden können.&lt;br /&gt;
&lt;br /&gt;
==Speicher mit Wasserkraftanlagen==&lt;br /&gt;
&lt;br /&gt;
Wasserkraftanlagen treten in Verbindung mit Speichern auf. Soll ein Laufwasserkraftwerk abgebildet werden, ist der zugehörende Gewässerabschnitt als Speicher zu definieren.&lt;br /&gt;
&lt;br /&gt;
In Abhängigkeit der Priorität von Wasserkraft gegenüber anderen Nutzungen gibt es verschiedene Konzepte zur Simulation von Turbinen. An den Talsperren der deutschen Mittelgebirgslagen tritt die Gewinnung von Wasserkraft in den meisten Fällen als Nebenprodukt auf. Dort nutzt man die Fallhöhe aus, um neben primären anderen Nutzungen einen weiteren Vorteil aus dem Bau einer Talsperre zu ziehen. Dort wird man versucht sein, immer genau dann Turbinen in Betrieb zu nehmen, wenn ausreichend Wasser zur Verfügung steht, ohne dabei konkurrierende Nutzungen zu beeinträchtigen.&lt;br /&gt;
&lt;br /&gt;
===Wasserkraft als Nebenprodukt===&lt;br /&gt;
&lt;br /&gt;
Hier bietet sich eine Näherungsberechnung an, welche die Turbinenabgabe in Abhängigkeit des aktuellen Wasserstandes, unter Beachtung von Schluckfähigkeit und Wirkungsgrad, definiert. Als Vereinfachung wird ein konstanter Unterwasserstand angenommen. Die notwendigen Berechnungsschritte sind im Folgenden gegeben:&lt;br /&gt;
&lt;br /&gt;
# Vorgabe mehrerer Stützstellen entlang des Speicherinhaltes &lt;br /&gt;
# Iterative Berechnung der Turbinenabgabe für alle Stützstellen unter Annahme eines konstanten Unterwasserstandes &lt;br /&gt;
# Vorgabe eines Grenzinhaltes, ab dem die Turbinenabgabe zugunsten anderer Nutzungen auf Null reduziert wird &lt;br /&gt;
# Abgabenfunktion der Speichernutzung &#039;Wasserkraft&#039; zuweisen &lt;br /&gt;
# Simulation &lt;br /&gt;
&lt;br /&gt;
Die Bestimmung der &#039;&#039;Abgabenfunktion&#039;&#039; für die Turbine ist somit als Vorleistung zu erbringen.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb48.gif|thumb|left|400px|Abbildung 48: Iterative Berechnung der Turbinenabgabe]]&lt;br /&gt;
&lt;br /&gt;
Es sei eine Turbine mit ihrem Wirkungsgrad gegeben. Bei Vorgabe einer erwünschten Leistung muss der Turbinendurchfluss iterativ berechnet werden, da Fallhöhe, Wirkungsgrad und Verlusthöhe vom Durchfluss abhängen. Wird der Wasserspiegel im Unterwasser als konstant angenommen, kann für beliebige Wasserstände im Speicher ein leistungsabhängiger Durchfluss berechnet werden. Die Annahme eines konstanten Unterwasserstandes erscheint im Hinblick auf Talsperren mit hohen und stark schwankenden Oberwasserständen aber wenig unterschiedlichen Unterwasserständen als Näherungslösung gerechtfertigt.&lt;br /&gt;
&lt;br /&gt;
Die gegenüber den Hauptnutzungen zurückgesetzte Priorität kommt durch das Zurücknehmen der Funktion auf Null zum Ausdruck. Ergebnis der Vorberechnung der Turbinenleistung ist eine eindeutige Funktion entlang des Speicherinhaltes.&lt;br /&gt;
&lt;br /&gt;
Durch Verschieben des Punktes &#039;S1&#039; nach rechts wird die Turbinenabgabe früher auf Null reduziert. Damit bleiben für andere Nutzungen mehr Reserven frei. Grundsätzlich ist bei der Aufstellung der Funktion auf den Wirkungsgradbereich zu achten und gegebenenfalls die Funktion entlang des Speicherinhaltes einzuschränken.&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb49.gif|thumb|center|600px|Abbildung 49: Beispiel einer speicherinhaltsabhängigen Turbinenabgabe bei konstantem Unterwasserstand]]&lt;br /&gt;
&lt;br /&gt;
===Wasserkraft als Hauptprodukt===&lt;br /&gt;
&lt;br /&gt;
Ist die Produktion von Wasserkraft Hauptziel des Talsperrenbetriebs, so steht die maximale Leistungsabgabe einer Turbine im Vordergrund. Für eine genauere Betrachtung sollte auch der Unterwasserstand korrekt einbezogen werden. Die Berechnungsreihenfolge ändert sich:&lt;br /&gt;
&lt;br /&gt;
# Ermittlung/Festlegung der Kenngrößen der Turbine. Dazu gehören die Leistung, maximale Schluckfähigkeit, durchflussabhängiger Wirkungsgrad und die Angabe durchflussabhängiger Verlusthöhen.&amp;lt;br/&amp;gt;Während der Simulation folgen die nächsten Berechnungsschritte: &lt;br /&gt;
# letzten Unterwasserstand abgreifen &lt;br /&gt;
# Iterative Berechnung des Turbinendurchflusses Q&amp;lt;sub&amp;gt;Turbine&amp;lt;/sub&amp;gt; mit einem geschätzten Wasserstand im Speicher &lt;br /&gt;
# Für den betroffenen Speicher erfolgt eine Inhalts- und Abgabenberechnung nach [[Umsetzung der Gesetzmäßigkeiten für die Simulation|Kapitel 2.3]] unter Berücksichtigung aller am Speicher wirkenden Nutzungen, wobei Q&amp;lt;sub&amp;gt;Turbine&amp;lt;/sub&amp;gt; konstant gehalten wird &lt;br /&gt;
# Vergleich der neuen und alten mittleren Wasserstände im Zeitintervall &lt;br /&gt;
# Ist das WSP-Abbruchkriterium nicht erreicht, neuen mittleren Wasserstand im Speicher schätzen und ab 3. die Berechnung wiederholen &lt;br /&gt;
&lt;br /&gt;
Auf diese Art erreicht die Turbine immer die erwünschte Leistung, solange die maximal mögliche Durchflussmenge des Auslasses nicht überschritten wird.&lt;br /&gt;
&lt;br /&gt;
Bei der Wasserkrafterzeugung als Hauptprodukt ergibt sich nun ein in Abhängigkeit des Ober- und Unterwasserstandes veränderlicher Turbinendurchfluss. Der wesentliche Unterschied zur Wasserkraftnutzung als Nebenprodukt liegt im variablen Unterwasserstand, der einmal höhere oder niedrigere Nettofallhöhen verursacht und dadurch die optimale Abgabe der Turbine beeinflusst.&lt;br /&gt;
&lt;br /&gt;
Ist beabsichtigt, nur für bestimmte Speicherinhalte eine Turbine auf optimaler Leistung zu fahren, kann die Turbine durch eine zusätzliche speicherinhaltsabhängige &#039;&#039;Abgabenfunktion&#039;&#039; oder eine &#039;&#039;Systemzustandsfunktion&#039;&#039; gemäß dem Faktorkonzept aus [[Betriebsregelkonzept|Kapitel 2]] beeinflusst werden. Diese wird zwischen 0 bis maximaler Speicherinhalt und für die y-Achse einheitenlos zwischen 0 und 1 definiert. Der Turbinendurchfluss dient als Faktor.&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM Theorie]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6833</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6833"/>
		<updated>2010-12-20T10:06:42Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Text hinzugefuegt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:Setup_BlueMMPC_englisch.png|thumb|BlueM.MPC modules]]&lt;br /&gt;
[[File:Workflow_BlueMMPC_deutsch.png|thumb|BlueM.MPC workflow]]&lt;br /&gt;
BlueM.MPC is a modular software consisting of three modules. The supervising module &#039;&#039;&#039;BlueM.MPC&#039;&#039;&#039; coordinates work and data flow. Module &#039;&#039;&#039;SWMM5&#039;&#039;&#039; represents the process model which is used for the evaluation of the objective function that is required by the optimization module &#039;&#039;&#039;[[BlueM.Opt]]&#039;&#039;&#039;. Data exchange between modules is based on text files.&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
Application of BlueM.MPC requires seven input files:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Process control:&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[XML-File]]:&#039;&#039;&#039; Inflow prediction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Optimization:&amp;lt;/u&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[OPT-Datei]]&#039;&#039;&#039;: Definition of optimization parameters&lt;br /&gt;
* &#039;&#039;&#039;[[ZIE-Datei]]&#039;&#039;&#039;: Definition of objective function&lt;br /&gt;
* &#039;&#039;&#039;[[MOD-Datei]]&#039;&#039;&#039;: Localization / identification of optimzation parameters in inp&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Process model:&amp;lt;/u&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[INP-File]]&#039;&#039;&#039;: Definition of the process model&lt;br /&gt;
* &#039;&#039;&#039;[[TXT-File]]&#039;&#039;&#039;: Inflow-Data&lt;br /&gt;
* &#039;&#039;&#039;[[HSF-File]]&#039;&#039;&#039;: Initial flows and water levels&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC GUI screenshot]]&lt;br /&gt;
&lt;br /&gt;
After starting the application &#039;&#039;&#039;MPC.exe&#039;&#039;&#039; a user form is opened. In this form all relevant information for the process control has to be filled in. After pressing the button &#039;&#039;Init BlueM.Opt&#039;&#039; the GUI of the optimizer &#039;&#039;&#039;[[BlueM.Opt]]&#039;&#039;&#039; is launched. The user selects an optimization algorithm and after setting the relevant optimization parameters the MPC simulation will start from there.&lt;br /&gt;
&lt;br /&gt;
The following informations are required in the BlueM.MPC form:&lt;br /&gt;
* &#039;&#039;Input File.&#039;&#039; Path and file name of the process model ([[INP-File]]).&lt;br /&gt;
* &#039;&#039;Output Folder.&#039;&#039; Path of the folder for results and log-files.&lt;br /&gt;
* &#039;&#039;Start.&#039;&#039; Date and time of the start of the MPC simulations.&lt;br /&gt;
* &#039;&#039;Stop.&#039;&#039; Date and time of the end of the MPC simulations.&lt;br /&gt;
* &#039;&#039;Control step.&#039;&#039; Length of the control horizon in minutes.&lt;br /&gt;
* &#039;&#039;Evaluation horizon.&#039;&#039; Length of the evaluation horizon in hours.&lt;br /&gt;
* &#039;&#039;Forecast handling.&#039;&#039; Selection of method, that determines how the time difference between the end of the forecast and the evaluation horizon is handled (see [[BlueMMPC_TimeHorizons]]). The user can choose between three methods: &lt;br /&gt;
# Set all inflow values to zero.&lt;br /&gt;
# Set all inflow values to the average of the forecast horizon of the node.&lt;br /&gt;
# Use the last value of the forecast horizon.&lt;br /&gt;
* &#039;&#039;Objective function threshold.&#039;&#039; An optional value to speed up the simulation can be set in cases where objective functions values are minimized towards zero (which is for example the case when overflow volumes are minimized). The user defines a threshold value, which is compared in each control loop to the calculated objective function of the first simulation run. If the calculated value is smaller than the given threshold value, the iterative calculation of optimal control values is not necessary.&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=XML-File&amp;diff=6832</id>
		<title>XML-File</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=XML-File&amp;diff=6832"/>
		<updated>2010-12-20T09:51:42Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;In BlueM.MPC, each inflow node in the sewer network can have its own forecast horizon and its own reliability factor. Forecast horizon and reliability factors are defined by meteostations. Theoretically, an unlimited number of meteostatins can be defined.  Each meteostation is described by four parameters:&lt;br /&gt;
&lt;br /&gt;
# &amp;lt;name&amp;gt;: Name of the meteostation.&lt;br /&gt;
# &amp;lt;nodename&amp;gt;: Name of the inflow node. The keyword &amp;quot;all&amp;quot; is used for all nodes without specified meteostations.&lt;br /&gt;
# &amp;lt;maxrange&amp;gt;: Length of the forecast horizon.&lt;br /&gt;
# &amp;lt;reliabiltyAtMaxrrange&amp;gt;: A linear function can be defined to each meteostation taking into account uncertainties in the forecast horizon. Possible values are positive real numbers. &lt;br /&gt;
&lt;br /&gt;
An example file is given below: &lt;br /&gt;
&lt;br /&gt;
&amp;lt;bluem&amp;gt;&lt;br /&gt;
&amp;lt;?xml version=&amp;quot;1.0&amp;quot; encoding=&amp;quot;utf-8&amp;quot;?&amp;gt;&lt;br /&gt;
&amp;lt;MeteoStationArray&amp;gt;&lt;br /&gt;
	&amp;lt;stations&amp;gt;&lt;br /&gt;
		&amp;lt;Meteostation&amp;gt;&lt;br /&gt;
			&amp;lt;name&amp;gt;default&amp;lt;/name&amp;gt;&lt;br /&gt;
			&amp;lt;nodename&amp;gt;all&amp;lt;/nodename&amp;gt;&lt;br /&gt;
			&amp;lt;maxrange&amp;gt;120&amp;lt;/maxrange&amp;gt;&lt;br /&gt;
			&amp;lt;reliabilityAtMaxrange&amp;gt;1.0&amp;lt;/reliabilityAtMaxrange&amp;gt;&lt;br /&gt;
		&amp;lt;/Meteostation&amp;gt;&lt;br /&gt;
	&amp;lt;/stations&amp;gt;&lt;br /&gt;
&amp;lt;/MeteoStationArray&amp;gt;&lt;br /&gt;
&amp;lt;/bluem&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=XML-File&amp;diff=6831</id>
		<title>XML-File</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=XML-File&amp;diff=6831"/>
		<updated>2010-12-20T09:51:02Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Text hinzugefuegt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;In BlueM.MPC, each inflow node in the sewer network can have its own forecast horizon and its own reliability factor. Forecast horizon and reliability factors are defined by meteostations. Theoretically, an unlimited number of meteostatins can be defined.  Each meteostation is described by four parameters:&lt;br /&gt;
&lt;br /&gt;
# &amp;lt;name&amp;gt;: Name of the meteostations&lt;br /&gt;
# &amp;lt;nodename&amp;gt;: Name of the inflow node. The keyword &amp;quot;all&amp;quot; is used for all nodes without specified meteostations.&lt;br /&gt;
# &amp;lt;maxrange&amp;gt;: Length of the forecast horizon.&lt;br /&gt;
# &amp;lt;reliabiltyAtMaxrrange&amp;gt;: A linear function can be defined to each meteostation taking into account uncertainties in the forecast horizon. Possible values are positive real numbers. &lt;br /&gt;
&lt;br /&gt;
An example file is given below: &lt;br /&gt;
&lt;br /&gt;
&amp;lt;bluem&amp;gt;&lt;br /&gt;
&amp;lt;?xml version=&amp;quot;1.0&amp;quot; encoding=&amp;quot;utf-8&amp;quot;?&amp;gt;&lt;br /&gt;
&amp;lt;MeteoStationArray&amp;gt;&lt;br /&gt;
	&amp;lt;stations&amp;gt;&lt;br /&gt;
		&amp;lt;Meteostation&amp;gt;&lt;br /&gt;
			&amp;lt;name&amp;gt;default&amp;lt;/name&amp;gt;&lt;br /&gt;
			&amp;lt;nodename&amp;gt;all&amp;lt;/nodename&amp;gt;&lt;br /&gt;
			&amp;lt;maxrange&amp;gt;120&amp;lt;/maxrange&amp;gt;&lt;br /&gt;
			&amp;lt;reliabilityAtMaxrange&amp;gt;1.0&amp;lt;/reliabilityAtMaxrange&amp;gt;&lt;br /&gt;
		&amp;lt;/Meteostation&amp;gt;&lt;br /&gt;
	&amp;lt;/stations&amp;gt;&lt;br /&gt;
&amp;lt;/MeteoStationArray&amp;gt;&lt;br /&gt;
&amp;lt;/bluem&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6820</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6820"/>
		<updated>2010-12-15T12:11:11Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:Setup_BlueMMPC_englisch.png|thumb|BlueM.MPC modules]]&lt;br /&gt;
[[File:Workflow_BlueMMPC_deutsch.png|thumb|BlueM.MPC workflow]]&lt;br /&gt;
BlueM.MPC is a modular software consisting of three modules. The supervising module &amp;quot;BlueM.MPC&amp;quot; coordinates work and data flow. Module &amp;quot;SWMM5&amp;quot; represents the process model which is used for the evaluation of the objective function that is required by the optimization module &amp;quot;BlueM.Opt&amp;quot;. Data exchange between modules is based on text files.&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
Application of BlueM.MPC requires seven input files:&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Process control:&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[XML-File]]:&#039;&#039;&#039; Inflow prediction&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Optimization:&amp;lt;/u&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[OPT-Datei]]&#039;&#039;&#039;: Definition of optimization parameters&lt;br /&gt;
* &#039;&#039;&#039;[[ZIE-Datei]]&#039;&#039;&#039;: Definition of objective function&lt;br /&gt;
* &#039;&#039;&#039;[[MOD-Datei]]&#039;&#039;&#039;: Localization / identification of optimzation parameters in inp&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Process model:&amp;lt;/u&amp;gt;&lt;br /&gt;
* &#039;&#039;&#039;[[INP-File]]&#039;&#039;&#039;: Definition of the process model&lt;br /&gt;
* &#039;&#039;&#039;[[TXT-File]]&#039;&#039;&#039;: Inflow-Data&lt;br /&gt;
* &#039;&#039;&#039;[[HSF-File]]&#039;&#039;&#039;: Initial flows and water levels&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC GUI screenshot]]&lt;br /&gt;
&lt;br /&gt;
For MPC simulations...&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=File:Workflow_BlueMMPC_deutsch.png&amp;diff=6819</id>
		<title>File:Workflow BlueMMPC deutsch.png</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=File:Workflow_BlueMMPC_deutsch.png&amp;diff=6819"/>
		<updated>2010-12-15T12:01:42Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6818</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6818"/>
		<updated>2010-12-15T12:01:18Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:Setup_BlueMMPC_englisch.png|thumb|BlueM.MPC modules]]&lt;br /&gt;
[[File:Workflow_BlueMMPC_deutsch.png|thumb|BlueM.MPC workflow]]&lt;br /&gt;
BlueM.MPC is a modular software consisting of three modules. Data exchange between modules is based on text files. The supervising module &amp;quot;BlueM.MPC&amp;quot; coordinates work and data flow. Module &amp;quot;SWMM5&amp;quot; represents the process model which is used for the evaluation of the objective function that is required by the optimization module &amp;quot;BlueM.Opt&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
Application of BlueM.MPC requires seven input files.&lt;br /&gt;
 &lt;br /&gt;
&#039;&#039;See also [[BlueM.MPC input files|input files]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC Screenshot]]&lt;br /&gt;
&lt;br /&gt;
For MPC simulations...&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=File:Setup_BlueMMPC_englisch.png&amp;diff=6817</id>
		<title>File:Setup BlueMMPC englisch.png</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=File:Setup_BlueMMPC_englisch.png&amp;diff=6817"/>
		<updated>2010-12-15T11:58:18Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=File:Setup_BlueMMPC.pdf&amp;diff=6816</id>
		<title>File:Setup BlueMMPC.pdf</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=File:Setup_BlueMMPC.pdf&amp;diff=6816"/>
		<updated>2010-12-15T11:56:32Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6815</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6815"/>
		<updated>2010-12-15T11:56:08Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
BlueM.MPC is a modular software consisting of three modules. Data exchange between modules is based on text files. The supervising module &amp;quot;BlueM.MPC&amp;quot; coordinates work and data flow. Module &amp;quot;SWMM5&amp;quot; represents the process model which is used for the evaluation of the objective function that is required by the optimization module &amp;quot;BlueM.Opt&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:Setup_BlueMMPC.pdf|thumb|BlueM.MPC modules]]&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
Application of BlueM.MPC requires seven input files.&lt;br /&gt;
 &lt;br /&gt;
&#039;&#039;See also [[BlueM.MPC input files|input files]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC Screenshot]]&lt;br /&gt;
&lt;br /&gt;
For MPC simulations...&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6814</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6814"/>
		<updated>2010-12-15T11:52:52Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
BlueM.MPC is a modular software consisting of three modules. Data exchange between modules is based on text files. The supervising module &amp;quot;BlueM.MPC&amp;quot; coordinates work and data flow. Module &amp;quot;SWMM5&amp;quot; represents the process model which is used for the evaluation of the objective function that is required by the optimization module &amp;quot;BlueM.Opt&amp;quot;.&lt;br /&gt;
&lt;br /&gt;
[[File:Aufbau_BlueMMPC.pdf|thumb|BlueM.MPC modules]]&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
Application of BlueM.MPC requires seven input files.&lt;br /&gt;
 &lt;br /&gt;
&#039;&#039;See also [[BlueM.MPC input files|input files]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC Screenshot]]&lt;br /&gt;
&lt;br /&gt;
For MPC simulations...&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6813</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6813"/>
		<updated>2010-12-15T11:36:20Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Model Predictive Control (MPC) of urban drainage systems */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 ({{:Literatur:Pleau-et-al_2005}}). MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned. Further information on MPC applications for urban drainage systems is given in {{:Literatur:Rauch-Harremoes_1999}} and {{:Literatur:Pirsing-et-al_2006}}.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6812</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6812"/>
		<updated>2010-12-15T11:35:35Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Model Predictive Control (MPC) of urban drainage systems */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 ({{:Literatur:Pleau-et-al_2005}}). MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned. Further information on the application of MPC systems is given in {{:Literatur:Rauch-Harremoes_1999}} and {{:Literatur:Pirsing-et-al_2006}}.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6811</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6811"/>
		<updated>2010-12-15T09:47:55Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 ({{:Literatur:Pleau-et-al_2005}}). MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned. Further information is given in {{:Literatur:Rauch-Harremoes_1999}} and {{:Literatur:Pirsing-et-al_2006}}.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6810</id>
		<title>Literature:Rauch-Harremoes 1999</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6810"/>
		<updated>2010-12-15T09:47:31Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{{1|Rauch &amp;amp; Harremoes (1999)}}}&amp;lt;ref name=&amp;quot;rauch-harremoes_2005&amp;quot;&amp;gt;&#039;&#039;&#039;Rauch, W., Harremoes, P.&#039;&#039;&#039; (1999): Genetic algorithms in real time control applied to minimize transient pollution from urban wastewater systems. Water Research, 33(5), 1265-1277, 1999.&amp;lt;/ref&amp;gt;&amp;lt;noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Vorschau==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6808</id>
		<title>Literature:Rauch-Harremoes 1999</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6808"/>
		<updated>2010-12-15T09:45:44Z</updated>

		<summary type="html">&lt;p&gt;Heusch: moved Literature:Pleau-Harremoes 1999 to Literature:Rauch-Harremoes 1999&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{{1|Rauch and Harremoes (1999)}}}&amp;lt;ref name=&amp;quot;rauch-harremoes_2005&amp;quot;&amp;gt;&#039;&#039;&#039;Rauch, W., Harremoes, P.&#039;&#039;&#039; (1999): Genetic algorithms in real time control applied to minimize transient pollution from urban wastewater systems. Water Research, 33(5), 1265-1277, 1999.&amp;lt;/ref&amp;gt;&amp;lt;noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Vorschau==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6807</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6807"/>
		<updated>2010-12-15T09:43:58Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau-et-al_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned. Further information is given in {{:Literatur:Rauch-Harremoes_1999}} and {{:Literatur:Pirsing-et-al_2006}}.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6806</id>
		<title>Literature:Rauch-Harremoes 1999</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Literature:Rauch-Harremoes_1999&amp;diff=6806"/>
		<updated>2010-12-15T09:42:49Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Created page with &amp;quot;{{{1|Rauch and Harremoes (1999)}}}&amp;lt;ref name=&amp;quot;rauch-harremoes_2005&amp;quot;&amp;gt;&amp;#039;&amp;#039;&amp;#039;Rauch, W., Harremoes, P.&amp;#039;&amp;#039;&amp;#039; (1999): Genetic algorithms in real time control applied to minimize transient po...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{{1|Rauch and Harremoes (1999)}}}&amp;lt;ref name=&amp;quot;rauch-harremoes_2005&amp;quot;&amp;gt;&#039;&#039;&#039;Rauch, W., Harremoes, P.&#039;&#039;&#039; (1999): Genetic algorithms in real time control applied to minimize transient pollution from urban wastewater systems. Water Research, 33(5), 1265-1277, 1999.&amp;lt;/ref&amp;gt;&amp;lt;noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Vorschau==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Literature:Pirsing-et-al_2006&amp;diff=6805</id>
		<title>Literature:Pirsing-et-al 2006</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Literature:Pirsing-et-al_2006&amp;diff=6805"/>
		<updated>2010-12-15T09:39:49Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Literatur hinzugefügt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{{1|Pirsing et al. (2006)}}}&amp;lt;ref name=&amp;quot;pirsing-et-al_2006&amp;quot;&amp;gt;&#039;&#039;&#039;Pirsing, A., Rosen, R., Obst, B., Montrone, F.&#039;&#039;&#039; (2006): Einsatz mathematischer Optimierungsverfahren bei der Abflusssteuerung in Kanalnetzen. GWF (Wasser - Abwasser), 147(5), 376-383, 2006.&amp;lt;/ref&amp;gt;&amp;lt;noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Vorschau==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6804</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6804"/>
		<updated>2010-12-15T09:35:55Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau-et-al_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned. Further information is given in Rauch and Harremoes (1999) {{:Literatur:Pleau-Harremoes_1999}} and Pirsing et al. (2006) {{:Literatur:Pirsing-et-al_2006}}.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6803</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6803"/>
		<updated>2010-12-15T09:31:32Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Model Predictive Control (MPC) of urban drainage systems==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau-et-al_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6802</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6802"/>
		<updated>2010-12-15T09:30:15Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Application */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. Off-line control systems are much more popular. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau-et-al_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations. The application of simplified flow routing models is possible but the ability to simulate flows correctly has to be questioned.&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=INP-File&amp;diff=6801</id>
		<title>INP-File</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=INP-File&amp;diff=6801"/>
		<updated>2010-12-14T14:02:38Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Created page with &amp;quot;Input file for SWMM5.&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Input file for SWMM5.&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6799</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6799"/>
		<updated>2010-12-14T13:43:58Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Anlegen der Seite&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
This page is an aid to the application of BlueM.MPC.&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
A BlueM.MPC dataset...&lt;br /&gt;
 &lt;br /&gt;
&#039;&#039;See also [[BlueM.MPC input files|input files]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC Screenshot]]&lt;br /&gt;
&lt;br /&gt;
For MPC simulations...&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6798</id>
		<title>BlueM.MPC application</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC_application&amp;diff=6798"/>
		<updated>2010-12-14T13:42:21Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Created page with &amp;quot;__NOTOC__ This page is an aid to the application of BlueM.  ==Dataset== A BlueM.MPC dataset...  &amp;#039;&amp;#039;See also Input files&amp;#039;&amp;#039;  ==Simulation== [[File:BlueMMPC_Use...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
This page is an aid to the application of BlueM.&lt;br /&gt;
&lt;br /&gt;
==Dataset==&lt;br /&gt;
A BlueM.MPC dataset... &lt;br /&gt;
&#039;&#039;See also [[BlueM Input Files|Input files]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Simulation==&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|BlueM.MPC Screenshot]]&lt;br /&gt;
&lt;br /&gt;
For individual simulations, it is easiest to use the &#039;&#039;&#039;[[BlueM.Win]]&#039;&#039;&#039; package.&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6797</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6797"/>
		<updated>2010-12-14T13:21:32Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau-et-al_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations.&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6796</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6796"/>
		<updated>2010-12-14T13:19:54Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations.&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;br /&gt;
&lt;br /&gt;
==Literature==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Literature:Pleau-et-al_2005&amp;diff=6795</id>
		<title>Literature:Pleau-et-al 2005</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Literature:Pleau-et-al_2005&amp;diff=6795"/>
		<updated>2010-12-14T13:17:39Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Created page with &amp;quot;{{{1|Pleau et al. (2005)}}}&amp;lt;ref name=&amp;quot;pleau-et-al_2005&amp;quot;&amp;gt;&amp;#039;&amp;#039;&amp;#039;Pleau, M., Colas, H., Lavallee, P., Pelletier, G., and Bonin, R.&amp;#039;&amp;#039;&amp;#039; (2005): Global optimal real-time control of the Que...&amp;quot;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{{1|Pleau et al. (2005)}}}&amp;lt;ref name=&amp;quot;pleau-et-al_2005&amp;quot;&amp;gt;&#039;&#039;&#039;Pleau, M., Colas, H., Lavallee, P., Pelletier, G., and Bonin, R.&#039;&#039;&#039; (2005): Global optimal real-time control of the Quebec urban drainage system. Environmental Modelling &amp;amp; Software, 20(2005), 401-413, &amp;lt;/ref&amp;gt;&amp;lt;noinclude&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Vorschau==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&amp;lt;/noinclude&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6794</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6794"/>
		<updated>2010-12-14T13:08:24Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999 {{:Literatur:Pleau_2005}}. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations.&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6793</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6793"/>
		<updated>2010-12-14T12:48:59Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Application */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control is a method that was first used for process control of chemical plants and oil refineries. MPC is conceptually a method for generating feedback control actions by continuously solving an open-loop optimal control problem over a finite control horizon. MPC systems are characterized by three principles:&lt;br /&gt;
&lt;br /&gt;
1. Implementation of a receding horizon strategy.&lt;br /&gt;
&lt;br /&gt;
2. Explicit use of a process model to predict future state developments of the&lt;br /&gt;
system.&lt;br /&gt;
&lt;br /&gt;
3. Application of optimization algorithms to calculate optimal control settings.&lt;br /&gt;
&lt;br /&gt;
For the operation of urban drainage systems only view MPC systems are in operation. The best known MPC system is the control system of the Quebec Urban Community (QUC) in Canada which is operation since 1999. MPC applications of sewer networks are so far not popular since the control constraints (i.e. the available time to calculate control decisions) place restrictions on the degree of sophistication of the process model and the optimization algorithm. In many other technical disciplines MPC is based on linear models. But flow processes in sewer network are highly nonlinear and the proper mathematical description of these processes is based on hyperbolic differential equations.&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6792</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6792"/>
		<updated>2010-12-14T11:26:16Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. These control decisions are usually stored in a database (rule-based control) and are available during operation without delay. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization. &lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control (or optimal control)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6791</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6791"/>
		<updated>2010-12-14T11:22:30Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
[[File:BlueMMPC_UserForm.png|thumb|User form of BlueM.MPC]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control (or optimal control)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=File:BlueMMPC_UserForm.png&amp;diff=6790</id>
		<title>File:BlueMMPC UserForm.png</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=File:BlueMMPC_UserForm.png&amp;diff=6790"/>
		<updated>2010-12-14T11:20:50Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Screenshot of BlueM.MPC-GUI&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Screenshot of BlueM.MPC-GUI&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6789</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6789"/>
		<updated>2010-12-14T11:15:45Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for the simulation of model predictive control (MPC) in sewer networks. MPC is an online strategy for real time control (RTC). Control decisions are calculated during operation with a process model and optimization algorithms. This feature distinguishes MPC from off-line control strategies, in which the control decisions are calculated during the design phase. BlueM.MPC implements [[SWMM | SWMM5]] for process modelling and [[BlueM.Opt | BlueM.Opt]] for optimization.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control (or optimal control)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6788</id>
		<title>BlueM.MPC</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.MPC&amp;diff=6788"/>
		<updated>2010-12-14T09:59:24Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.MPC is a software for model predictive control (MPC) simulations.&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
Model predictive control (or optimal control)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC application|BlueM.MPC User Manual]]&#039;&#039;&#039;&lt;br /&gt;
* Documentation of the [[BlueM.MPC input files|input files]]&lt;br /&gt;
* Documentation of the [[BlueM.MPC output files|output files]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Template:BlueM.Opt_nav&amp;diff=6787</id>
		<title>Template:BlueM.Opt nav</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Template:BlueM.Opt_nav&amp;diff=6787"/>
		<updated>2010-12-14T09:49:41Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&amp;lt;div style=&amp;quot;text-align:center; background-color:#CFFFD1; padding:2px; margin-bottom:5px; border:1px solid black;&amp;quot;&amp;gt;&lt;br /&gt;
{{EVO Icon}} &#039;&#039;&#039;[[BlueM.Opt]]&#039;&#039;&#039; | [[BlueM.Opt Downloads|Downloads]] | [[BlueM.Opt Anwendung|Application]] | [[BlueM.Opt Development|Development]] | [http://bugs.bluemodel.org/buglist.cgi?bug_status=UNCONFIRMED&amp;amp;bug_status=NEW&amp;amp;bug_status=ASSIGNED&amp;amp;bug_status=REOPENED&amp;amp;content=&amp;amp;product=BlueM.Opt&amp;amp;query_format=specific&amp;amp;order=bug_severity%2Cpriority%20ASC&amp;amp;query_based_on= Bugs] | [[Intern:EVO.NET SVN|SVN]]&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.Opt&amp;diff=6786</id>
		<title>BlueM.Opt</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.Opt&amp;diff=6786"/>
		<updated>2010-12-14T09:48:52Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Usage */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{EVO.NET_nav}}&lt;br /&gt;
[[File:Simulation-based-optimization.png|thumb|Simulation-based optimization]]&lt;br /&gt;
[[File:EVO Box screenshot.png|thumb|Screenshot]]&lt;br /&gt;
[[File:Scatterplot screenshot.png|thumb|Scatterplot Matrix]]&lt;br /&gt;
==Description==&lt;br /&gt;
BlueM.Opt is an optimization framework that can be coupled with an arbitrary simulation software (only current requirement: input data and results are to be stored in ASCII format). The optimization parameters, objective functions and (optionally) boundary conditions are defined in a flexible manner.&lt;br /&gt;
&lt;br /&gt;
Optimization results are stored in a database. &lt;br /&gt;
&lt;br /&gt;
BlueM.Opt integrates a graphing feature for displaying the optimization progress and results. Optimization results can also be analyzed in detail.&lt;br /&gt;
&lt;br /&gt;
Where possible, BlueM.Opt utilizes multithreading in order to evaluate multiple parameter sets simultaneously. &lt;br /&gt;
&lt;br /&gt;
List of available methods (optimization algorithms):&lt;br /&gt;
* &#039;&#039;&#039;[[PES]]&#039;&#039;&#039;: Parametric Evolution Strategy&lt;br /&gt;
* &#039;&#039;&#039;[[CES]]&#039;&#039;&#039;: Combinatorial Evolution Strategy&lt;br /&gt;
* &#039;&#039;&#039;[[HYBRID]]&#039;&#039;&#039;: Combination of PES and CES&lt;br /&gt;
* &#039;&#039;&#039;[[Hooke &amp;amp; Jeeves]]&#039;&#039;&#039;: Hillclimbing Algorithm&lt;br /&gt;
* &#039;&#039;&#039;[[MetaEvo]]&#039;&#039;&#039;: multicritera, hybrid optimization algorithm&lt;br /&gt;
* &#039;&#039;&#039;[[DDS]]&#039;&#039;&#039;: Dynamically Dimensioned Search&lt;br /&gt;
another method is&lt;br /&gt;
* &#039;&#039;&#039;[[SensiPlot]]&#039;&#039;&#039;: Sensitivity analysis (no optimization)&lt;br /&gt;
* &#039;&#039;&#039;[[TSP]]&#039;&#039;&#039; (only for [[Traveling Salesman]])&lt;br /&gt;
&lt;br /&gt;
List of currently implemented applications (simulation models):&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.Sim]]&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;[[SMUSI]]&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;[[S::CAN]]&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;[[SWMM]]&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;[[Test problems]]&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;[[Traveling Salesman]]&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Downloads==&lt;br /&gt;
* [[BlueM.Opt Downloads]]&lt;br /&gt;
&lt;br /&gt;
==Application==&lt;br /&gt;
* &#039;&#039;&#039;[[EVO.NET Anwendung|BlueM.Opt User manual]]&#039;&#039;&#039; ([[EVO.NET Doku Export|PDF-Export]])&lt;br /&gt;
** Documentation of the [[EVO.NET Eingabedateien | input files]]&lt;br /&gt;
** Documentation of the [[EVO.NET Ausgabedateien | output files]]&lt;br /&gt;
&lt;br /&gt;
==Development==&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.Opt Development]]&#039;&#039;&#039;&lt;br /&gt;
** [[BlueM.Opt Begriffsklärung | Glossary]]&lt;br /&gt;
** Documentation of the [[BlueM.Opt Code|code]]&lt;br /&gt;
** Bug tracking: [http://130.83.196.154/bugzilla/buglist.cgi?query_format=specific&amp;amp;order=priority+asc&amp;amp;bug_status=__open__&amp;amp;product=BlueM.Opt&amp;amp;content= Bugzilla]&lt;br /&gt;
** [[BlueM.Opt compilation |Compilation]]&lt;br /&gt;
&lt;br /&gt;
==Internal==&lt;br /&gt;
* Documentation of the [[Intern:Bluem:Opt SVN | SVN Repository]]&lt;br /&gt;
&lt;br /&gt;
[[Category:BlueM.Opt]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Main_Page&amp;diff=6785</id>
		<title>Main Page</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Main_Page&amp;diff=6785"/>
		<updated>2010-12-14T09:41:59Z</updated>

		<summary type="html">&lt;p&gt;Heusch: BlueM.MPC hinzugefügt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOEDITSECTION__&lt;br /&gt;
&amp;lt;big&amp;gt;&#039;&#039;&#039;Wiki for the BlueM software package of the Section of Engineering Hydrology and Water Management ([http://www.ihwb.tu-darmstadt.de/ ihwb]) of TU Darmstadt.&#039;&#039;&#039;&amp;lt;/big&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;background-color:#CFE9FF; border:1px solid #cccccc; padding:5px;&amp;quot;&amp;gt;&lt;br /&gt;
==Description==&lt;br /&gt;
[[File:Ihwb-logo-athene.gif|right]]&lt;br /&gt;
BlueM is a software package for river basin management developed by [http://www.ihwb.tu-darmstadt.de ihwb - Technische Universität Darmstadt]. It allows for the integrated simulation, analysis and optimisation of discharge and pollution loads in rural and urban catchments, including processes in the water body, using physically-based hydrologic approaches. BlueM is the result of continuous development efforts based on model concepts that have been pursued at ihwb for many years and have already been implemented in various applications.&lt;br /&gt;
&lt;br /&gt;
Besides the hydrological model core for rainfall-runoff computations including discharge, pollution load and water quality processes in rural and urban catchments ([[BlueM.Sim]]), the BlueM software package also contains tools for visualizing and analyzing time series ([[Wave|BlueM.Wave]]), for optimizing, auto-calibrating and performing sensitivity analyses on model parameters ([[BlueM.Opt]]), as well as for visualizing optimization results (e.g. in the form of scatterplot matrices). A further package component is [[BlueM.Analyser]], a tool for carrying out monitoring and assessment tasks in real-time (per time step).&lt;br /&gt;
&lt;br /&gt;
BlueM.Sim and BlueM.Analyser are equipped with [http://www.openmi.org/ OpenMI-interfaces], which allows them to be coupled with other OpenMI-compliant models.&lt;br /&gt;
&lt;br /&gt;
BlueM components:&lt;br /&gt;
&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.Sim]]&#039;&#039;&#039; (hydrologic computational core – with OpenMI-interface)&lt;br /&gt;
* &#039;&#039;&#039;[[Wave|BlueM.Wave]]&#039;&#039;&#039; (time series management and analysis tool)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.Opt]]&#039;&#039;&#039; (optimization based on evolutionary algorithms and sensitivity analysis)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.Analyser]]&#039;&#039;&#039; (real-time data monitoring and evaluation tool – coupled via OpenMI)&lt;br /&gt;
* &#039;&#039;&#039;[[BlueM.MPC]]&#039;&#039;&#039; (model predictive control with BlueM.Opt and SWMM5)&lt;br /&gt;
&lt;br /&gt;
The software package BlueM is freely available after registration. It is also possible to access the source code for research purposes (requires an agreement with [http://www.ihwb.tu-darmstadt.de ihwb]). Further information can be found in the [[BlueM License|License / Terms of Use]].&lt;br /&gt;
&lt;br /&gt;
Also see the detailed [[Intern:BlueM_Beschreibung|description]] of the program package (&#039;&#039;currently only available internally&#039;&#039;)&lt;br /&gt;
&lt;br /&gt;
Publications about BlueM and projects in which BlueM was used are listed [[BlueM Referenzen|here]].&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;background-color:#CFFFD1; border:1px solid #cccccc; padding:5px; margin-top:10px;&amp;quot;&amp;gt;&lt;br /&gt;
==Documentation==&lt;br /&gt;
:{{BlueM Icon}} &#039;&#039;&#039;[[BlueM.Sim]]: Continuous rainfall-runoff and reservoir simulation model&#039;&#039;&#039;&lt;br /&gt;
::[[BlueM.Sim downloads|Downloads]] | [[BlueM.Sim application|Application]] | [[BlueM Theorie Index|Theory]] | [[BlueM Code|Code]] | [http://bugs.bluemodel.org/buglist.cgi?bug_status=UNCONFIRMED&amp;amp;bug_status=NEW&amp;amp;bug_status=ASSIGNED&amp;amp;bug_status=REOPENED&amp;amp;content=&amp;amp;product=BlueM.Sim&amp;amp;query_format=specific&amp;amp;order=bug_severity%2Cpriority%20ASC&amp;amp;query_based_on= Bugs] | [[Intern:BlueM SVN|SVN]]&lt;br /&gt;
&lt;br /&gt;
:{{EVO Icon}} &#039;&#039;&#039;[[BlueM.Opt]]: Optimization Framework&#039;&#039;&#039;&lt;br /&gt;
::[[BlueM.Opt Downloads|Downloads]] | [[BlueM.Opt Anwendung|Application]] | [[BlueM.Opt Development|Development]] | [http://bugs.bluemodel.org/buglist.cgi?bug_status=UNCONFIRMED&amp;amp;bug_status=NEW&amp;amp;bug_status=ASSIGNED&amp;amp;bug_status=REOPENED&amp;amp;content=&amp;amp;product=BlueM.Opt&amp;amp;query_format=specific&amp;amp;order=bug_severity%2Cpriority%20ASC&amp;amp;query_based_on= Bugs] | [[Intern:EVO.NET SVN|SVN]]&lt;br /&gt;
&lt;br /&gt;
:{{Wave Icon}} &#039;&#039;&#039;[[Wave]]: Tool for displaying and analysing time series&#039;&#039;&#039;&lt;br /&gt;
::[[Wave:Code|Code]] | [http://bugs.bluemodel.org/buglist.cgi?bug_status=UNCONFIRMED&amp;amp;bug_status=NEW&amp;amp;bug_status=ASSIGNED&amp;amp;bug_status=REOPENED&amp;amp;content=&amp;amp;product=Wave&amp;amp;query_format=specific&amp;amp;order=bug_severity%2Cpriority%20ASC&amp;amp;query_based_on= Bugs] | [[Intern:Wave SVN|SVN]]&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;background-color:#f1f1f1; border:1px solid #cccccc; padding:5px; margin-top:10px;&amp;quot;&amp;gt;&lt;br /&gt;
==[[BlueM:Current events|Current events]]==&lt;br /&gt;
&amp;lt;div style=&amp;quot;height:200px; overflow:auto; border:1px dotted black; padding:0 10px 10px 5px; margin:10px;&amp;quot;&amp;gt;{{:BlueM:Current events}}&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;background-color:#FEFFBF; border:1px solid #cccccc; padding:5px; margin-top:10px;&amp;quot;&amp;gt;&lt;br /&gt;
==Help==&lt;br /&gt;
This wiki contains detailed descriptions of the application and of the theory behind the individual software components.&lt;br /&gt;
&lt;br /&gt;
Additional resources:&lt;br /&gt;
* [[Help:Contents|Help]] for dealing with the wiki&lt;br /&gt;
* [[FAQ|Frequently Asked Questions (FAQ)]]&lt;br /&gt;
* A [http://forum.bluemodel.org/ Forum] is available for discussion&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;div style=&amp;quot;background-color:#FFDFDF; border:1px solid #cccccc; padding:5px; margin-top:10px;&amp;quot;&amp;gt;&lt;br /&gt;
==Collaboration==&lt;br /&gt;
All visitors to this site are invited to use and improve upon the projects! &lt;br /&gt;
* The &#039;&#039;&#039;documentation&#039;&#039;&#039; in this Wiki - for editing the wiki you need a [http://wiki.bluemodel.org/index.php?title=Special:UserLogin&amp;amp;type=signup&amp;amp;returnto=Main_Page user account]. &lt;br /&gt;
* The &#039;&#039;&#039;source code&#039;&#039;&#039;. All issues (including bugs, but also suggestions for improvement) are managed in the  [http://bugs.bluemodel.org/ Bugzilla] installation. This is where you can enter new issues, discuss them, and upload patches.&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=OBF-file&amp;diff=6776</id>
		<title>OBF-file</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=OBF-file&amp;diff=6776"/>
		<updated>2010-03-30T10:26:46Z</updated>

		<summary type="html">&lt;p&gt;Heusch: SWMM-Keywords korrigiert&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Vorlage:BlueM.Opt Eingabedateien}}&lt;br /&gt;
&amp;lt;div class=&amp;quot;info_versionen&amp;quot;&amp;gt;&lt;br /&gt;
&#039;&#039;&#039;Versionen:&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;aktuell&#039;&#039;&#039; v1.4 (ab r1524)&lt;br /&gt;
* [{{SERVER}}/bluem/wiki/index.php?title=ZIE-Datei&amp;amp;oldid=6096 v1.3] (ab r1436)&lt;br /&gt;
* [{{SERVER}}/bluem/wiki/index.php?title=ZIE-Datei&amp;amp;oldid=5843 v1.2.x]&lt;br /&gt;
&amp;lt;/div&amp;gt;&lt;br /&gt;
&amp;lt;div style=&amp;quot;float:left; margin:0 10px 10px 0;&amp;quot;&amp;gt;__TOC__&amp;lt;/div&amp;gt;&lt;br /&gt;
Diese Datei definiert die Ziele für die Optimierung. Jede Zeile entspricht einer Zielfunktion.&lt;br /&gt;
&lt;br /&gt;
Die Datei muss den gleichen Namen wie der Simulations-Datensatz haben, aber mit der Endung &#039;&#039;&#039;.ZIE&#039;&#039;&#039;, und muss sich im Simulations-Arbeitsverzeichnis befinden. &amp;lt;br clear=&amp;quot;all&amp;quot;/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
The file is divided into several blocks, each of which is optional. Each block is identified by its heading:&lt;br /&gt;
* &#039;&#039;&#039;Series&#039;&#039;&#039;: This block defines objective functions that are based on a comparison of simulation time series with a reference time series.&lt;br /&gt;
* &#039;&#039;&#039;Values&#039;&#039;&#039;: This block defines objective functions that are based on a comparison of simulation result values with a reference value (so far only functional for [[SWMM]] applications, see Bug 414).&lt;br /&gt;
* &#039;&#039;&#039;ValueFromSeries&#039;&#039;&#039;: This block defines objective functions that are based on a comparison of values that are computed from simulation time series with reference values.&lt;br /&gt;
* &#039;&#039;&#039;IHA-Analysis&#039;&#039;&#039;: This block defines objective functions based on the Indicators of Hydrologic Alteration (IHA).&lt;br /&gt;
* &#039;&#039;&#039;SKos&#039;&#039;&#039;: Damages and Costs&lt;br /&gt;
* &#039;&#039;&#039;Aggregate&#039;&#039;&#039;: Aggregate objective functions&lt;br /&gt;
&lt;br /&gt;
==File format==&lt;br /&gt;
&amp;lt;bluem&amp;gt;&lt;br /&gt;
*Objective functions&lt;br /&gt;
*===================&lt;br /&gt;
*&lt;br /&gt;
*Series&lt;br /&gt;
*------&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------------------|------------------|----------------------------------------|---------|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R | OpFak | Datei | SimGröße   | ZielFkt |        Evaluierungs Zeitraum         |         Referenzreihe                  | IstWert |&lt;br /&gt;
*|     |               |         |   |       |       |            |         |        Start      |     Ende         | RefGröße | Datei                       |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------------------|------------------|----------|-----------------------------|---------|&lt;br /&gt;
 |  P  | NashSutcliffe |         | - |       |  WEL  | B401       | NashSutt|  30.05.1984 00:00 | 18.06.1984 23:30 |          | Zeitreihe.zre               |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------------------|------------------|----------|-----------------------------|---------|&lt;br /&gt;
*&lt;br /&gt;
*Values&lt;br /&gt;
*------&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|------------------|----------------|---------|---------|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R | OpFak | Datei |   SimGröße | ZielFkt | Zielgröße        | OptGröße       |         | IstWert |&lt;br /&gt;
*|     |               |         |   |       |       |            |         | (Block)          | (Spalte)       | RefWert |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|------------------|----------------|---------|---------|&lt;br /&gt;
 |  P  | OutfallLoad   |         | - |       |  RPT  |            |  Diff   | OutfallNode      | AvgFlow        |     0   |         |&lt;br /&gt;
 |  S  | Speicher      | Becken  | - |    +  |  BLZ  | B401       |         | Speicher         | maxVolume      |         |         |&lt;br /&gt;
 |  S  | Speicher      | Becken  | - |    +  |  BLZ  | B701       |         | Speicher         | maxVolume      |         |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|------------------|----------------|---------|---------|&lt;br /&gt;
*&lt;br /&gt;
*ValueFromSeries&lt;br /&gt;
*---------------&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------|------|-------------------|---------|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R | OpFak | Datei |   SimGröße | ZielFkt | EvalZeitraum |   Referenzwert    | IstWert |&lt;br /&gt;
*|     |               |         |   |       |       |            |         | Start | Ende | WertTyp | RefWert |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------|------|---------|---------|---------|&lt;br /&gt;
 |  P  | OutfallLoad   |         | - |       |  WEL  | B401_2AB   |  Diff   |       |      |         |         |         |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|---------|-------|------|---------|---------|---------|&lt;br /&gt;
*&lt;br /&gt;
*IHA-Analysis&lt;br /&gt;
*------------&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|-----------|-------------------------------|----------|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R | OpFak | Datei | SimGröße   | ZielFkt   |         Referenzreihe         | IstWert  |&lt;br /&gt;
*|     |               |         |   |       |       |            |           | RefGröße | Datei              |          |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|-----------|----------|--------------------|----------|&lt;br /&gt;
 |  P  | IHAGesamt     |         |   |       | WEL   | S09 _1ZU   |           | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
 |  S  | IHAQuantity   |         |   |       | WEL   | S09 _1ZU   | Quantity  | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
 |  S  | IHAExtremes   |         |   |       | WEL   | S09 _1ZU   | Extremes  | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
 |  S  | IHATiming     |         |   |       | WEL   | S09 _1ZU   | Timing    | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
 |  S  | IHAFrequency  |         |   |       | WEL   | S09 _1ZU   | Frequency | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
 |  S  | IHARate       |         |   |       | WEL   | S09 _1ZU   | Rate      | TOLF_1ZU | ZRE\Olef_orig.wel  |          |&lt;br /&gt;
*|-----|---------------|---------|---|-------|-------|------------|-----------|----------|--------------------|----------|&lt;br /&gt;
*&lt;br /&gt;
*SKos&lt;br /&gt;
*----&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|-------|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R | OpFak |&lt;br /&gt;
*|     |               |         |   |       |&lt;br /&gt;
*|-----|---------------|---------|---|-------|&lt;br /&gt;
 |  P  | Baukosten     |         |   |       |&lt;br /&gt;
*|-----|---------------|---------|---|-------|&lt;br /&gt;
*&lt;br /&gt;
*Aggregate&lt;br /&gt;
*---------&lt;br /&gt;
*&lt;br /&gt;
*|-----|---------------|---------|---|&lt;br /&gt;
*| Opt | Bezeichnung   | Gruppe  | R |&lt;br /&gt;
*|-----|---------------|---------|---|&lt;br /&gt;
 |  P  | Beckengesamt  | Becken  |   |&lt;br /&gt;
*|-----|---------------|---------|---|&lt;br /&gt;
&amp;lt;/bluem&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Die Breite der Spalten darf bei Bedarf angepasst werden, nur alle &amp;quot;|&amp;quot;-Zeichen müssen erhalten bleiben!&lt;br /&gt;
&lt;br /&gt;
Ein &amp;quot;&amp;lt;code&amp;gt;*&amp;lt;/code&amp;gt;&amp;quot; am Anfang einer Zeile führt dazu, dass die Zeile ignoriert wird.&lt;br /&gt;
&lt;br /&gt;
==Explanation==&lt;br /&gt;
===Common parameters===&lt;br /&gt;
The blocks &amp;quot;Series&amp;quot;, &amp;quot;Values&amp;quot;, &amp;quot;ValuesFromSeries&amp;quot; and &amp;quot;IHA-Analyses&amp;quot; share a set of parameters.&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;150&amp;quot; | Parameter !! width=&amp;quot;500&amp;quot; | Beschreibung&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Opt&#039;&#039;&#039; || Angabe, ob es sich um ein &#039;&#039;Primärziel&#039;&#039; handelt (&amp;lt;code&amp;gt;P&amp;lt;/code&amp;gt;) oder nicht (&amp;lt;code&amp;gt;N&amp;lt;/code&amp;gt;). Wenn nicht, handelt es sich um ein &#039;&#039;Sekundärziel&#039;&#039;, die zwar immer ausgewertet wird, aber nicht für die Optimierung herangezogen wird.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Bezeichnung&#039;&#039;&#039; || Bezeichnung des Ziels (beliebig)&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Gruppe&#039;&#039;&#039; || Group name for aggregated objective functions&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;R&#039;&#039;&#039;ichtung&lt;br /&gt;
|&lt;br /&gt;
*&amp;lt;code&amp;gt;-&amp;lt;/code&amp;gt;: Die Zielfunktion soll minimiert werden (Standard)&lt;br /&gt;
*&amp;lt;code&amp;gt;+&amp;lt;/code&amp;gt;: Die Zielfunktion soll maximiert werden (hierzu wird der evaluierte Zielwert mit -1 multipliziert, siehe Bug 303)&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Op&#039;&#039;&#039;erator oder &#039;&#039;&#039;Fak&#039;&#039;&#039;tor&lt;br /&gt;
|&lt;br /&gt;
*&amp;lt;code&amp;gt;+&amp;lt;/code&amp;gt;: Der Zielwert wird zur Gruppe addiert&lt;br /&gt;
*&amp;lt;code&amp;gt;-&amp;lt;/code&amp;gt;: Der Zielwert wird von der Gruppe subtrahiert&lt;br /&gt;
*&amp;lt;code&amp;gt;2; 0.5; -10&amp;lt;/code&amp;gt;: Ein Faktor, mit dem der Zielwert multipliziert und dann zur Gruppe addiert wird.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Datei&#039;&#039;&#039; || Die Ergebnisdatei, aus der das Simulationsergebnis ausgelesen werden soll [WEL, KWL, ASC, &amp;lt;del&amp;gt;BIL, PRB&amp;lt;/del&amp;gt; (Bug 220)]&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SimGröße&#039;&#039;&#039; || Die Simulationsgröße, auf dessen Basis der Qualitätswert berechnet werden soll&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;ZielFkt&#039;&#039;&#039; || Gibt an welche Zielfunktion verwendet werden soll.&lt;br /&gt;
* &amp;lt;code&amp;gt;AbQuad&amp;lt;/code&amp;gt;: Abweichung der Fehlerquadrate&lt;br /&gt;
* &amp;lt;code&amp;gt;NashSutt&amp;lt;/code&amp;gt;: Nash-Sutcliffe Koeffizient{{:Literatur:Nash-Sutcliffe_1970|}}&lt;br /&gt;
:abgeänderte Formel mit &amp;lt;code&amp;gt;0 &amp;lt; E &amp;lt; &amp;amp;infin;&amp;lt;/code&amp;gt; :&lt;br /&gt;
:&amp;lt;math&amp;gt;E=\frac{\sum_{t=1}^T\left(Q_{gem}^t-Q_{sim}^t\right)^2}{\sum_{t=1}^T\left(Q_{gem}^t-\overline{Q_{gem}}\right)^2}&amp;lt;/math&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Diff&amp;lt;/code&amp;gt;: Differenz&lt;br /&gt;
* &amp;lt;code&amp;gt;nÜber&amp;lt;/code&amp;gt;: Relative Anzahl der Zeitschritte mit Überschreitung des Referenzwerts/der Referenzreihe [%]&lt;br /&gt;
* &amp;lt;code&amp;gt;sÜber&amp;lt;/code&amp;gt;: Summe der Überschreitungen des Referenzwerts/der Referenzreihe&lt;br /&gt;
* &amp;lt;code&amp;gt;nUnter&amp;lt;/code&amp;gt;: Relative Anzahl der Zeitschritte mit Unterschreitung des Referenzwerts/der Referenzreihe [%]&lt;br /&gt;
* &amp;lt;code&amp;gt;sUnter&amp;lt;/code&amp;gt;: Summe der Unterschreitungen des Referenzwerts/der Referenzreihe&lt;br /&gt;
* &amp;lt;code&amp;gt;Korr&amp;lt;/code&amp;gt;: [http://de.wikipedia.org/wiki/Bestimmtheitsma%C3%9F Bestimmtheitsmaß] (einfache lineare Regression) &amp;lt;code&amp;gt;0 &amp;amp;le; R² &amp;amp;le; 1&amp;lt;/code&amp;gt;:&lt;br /&gt;
:&amp;lt;math&amp;gt;R^2 = \frac{s^2_{xy}}{s^2_x \cdot s^2_y}&amp;lt;/math&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Volf&amp;lt;/code&amp;gt;: Volumenfehler [%]&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;IstWert&#039;&#039;&#039;&amp;lt;br/&amp;gt;(optional) || Ein Wert, der in den Diagrammen als Vergleichswert angezeigt wird.&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===&amp;quot;Series&amp;quot;===&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;150&amp;quot; | Parameter !! width=&amp;quot;500&amp;quot; | Beschreibung&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;EvalZeitraum&#039;&#039;&#039;&amp;lt;br/&amp;gt;(optional) || Bestimmt den Zeitraum, für den die Zielfunktion ausgewertet werden soll.&amp;lt;br/&amp;gt;&lt;br /&gt;
Format: &amp;lt;code&amp;gt;dd.mm.yyyy hh:mm&amp;lt;/code&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
Wenn nicht angegeben, wird der Simulationszeitraum verwendet.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefGröße&#039;&#039;&#039;&amp;lt;br/&amp;gt;(nur bei Referenzreihen und .WEL als Referenzdatei) || Gibt an welche Spalte der .WEL Referenzdatei zum Vergleich herangezogen werden soll.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefDatei&#039;&#039;&#039; || Der Dateiname der Referenzreihe ([[ZRE-Format|.zre]] oder [[WEL-Format|.wel]])&amp;lt;br/&amp;gt;&amp;lt;span style=&amp;quot;color:red&amp;quot;&amp;gt;&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Die Zeitschrittweite der Referenzreihe muss mit dem Zeitschritt der Simulation übereinstimmen! (siehe Bug 218)&amp;lt;/span&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===&amp;quot;Values&amp;quot;===&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;150&amp;quot; | Parameter !! width=&amp;quot;500&amp;quot; | Beschreibung&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Zielgröße (Block)&#039;&#039;&#039; || Angabe, in welchem Abschnitt (Block) sich die Zielvariable befindet.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;OptGröße (Spalte)&#039;&#039;&#039; || Angabe der Zielvariablen im Block.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefWert&#039;&#039;&#039; || Der zu vergleichende Referenzwert&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bei jeder Anwendung ist der Parameter OptGröße an die jeweilige Zielgröße gebunden, es gibt also nur bestimmte Kombinationen.&lt;br /&gt;
&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;100&amp;quot; | Anwendung  !! width=&amp;quot;200&amp;quot; | Zielgröße (Block) !! width=&amp;quot;200&amp;quot; | OptGröße (Spalte)&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || NodeFlooding || HoursFlooded&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || NodeFlooding || FloodVolume&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || StorageVolume || AvgVolume&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || StorageVolume || AvgPctFull&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || StorageVolume || MaxVolume&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || StorageVolume || MaxPctFull&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || StorageVolume || MaxOutflow&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || OutfallLoad || MaxFlow&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || OutfallLoad || FlowVolume&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || OutfallLoad || Pollutant_[no]&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || Pumping || OnlineTime&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;SWMM&#039;&#039;&#039; || Pumping || TotalEnergy&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Smusi&#039;&#039;&#039; || EntlVolumen || SumVol&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Smusi&#039;&#039;&#039; || MaxAbfluss || Qmax&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;Smusi&#039;&#039;&#039; || EntlFracht || CSBspez&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
Bei der OptGröße Pollutant_[no] können bis zu fünf Stoffe ausgewertet werden, für [no] ist dann entsprechend 01 / 02 / 03 / 04 / 05 einzusetzen, also z.B. Pollutant_02 für den zweiten Stoffparameter.&lt;br /&gt;
&lt;br /&gt;
===&amp;quot;ValueFromSeries&amp;quot;===&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;150&amp;quot; | Parameter !! width=&amp;quot;500&amp;quot; | Beschreibung&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;EvalZeitraum&#039;&#039;&#039;&amp;lt;br/&amp;gt;(optional) || Bestimmt den Zeitraum, für den die Zielfunktion ausgewertet werden soll.&amp;lt;br/&amp;gt;&lt;br /&gt;
Format: &amp;lt;code&amp;gt;dd.mm.yyyy hh:mm&amp;lt;/code&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
Wenn nicht angegeben, wird der Simulationszeitraum verwendet.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;WertTyp&#039;&#039;&#039; || Gibt an wie der Wert, der mit dem Referenzwert verglichen werden soll, aus dem Simulationsergebnis berechnet werden soll.&lt;br /&gt;
* &amp;lt;code&amp;gt;MaxWert&amp;lt;/code&amp;gt;: Maximaler Wert des Simulationsergebnisses&lt;br /&gt;
* &amp;lt;code&amp;gt;MinWert&amp;lt;/code&amp;gt;: Minimaler Wert des Simulationsergebnisses&lt;br /&gt;
* &amp;lt;code&amp;gt;Average&amp;lt;/code&amp;gt;: Durchschnittlicher Wert des Simulationsergebnisses&lt;br /&gt;
* &amp;lt;code&amp;gt;AnfWert&amp;lt;/code&amp;gt;: Der erste wert des Simulationsergebnisses&lt;br /&gt;
* &amp;lt;code&amp;gt;EndWert&amp;lt;/code&amp;gt;: Der letzte Wert des Simulationsergebnisses&lt;br /&gt;
* &amp;lt;code&amp;gt;Summe&amp;lt;/code&amp;gt;: Summe des Simulationsergebnisses&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefWert&#039;&#039;&#039; || Der zu vergleichende Referenzwert&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
===&amp;quot;IHA-Analysis&amp;quot;===&lt;br /&gt;
In an IHA-Analysis, a simulated flow regime as specified under &amp;lt;code&amp;gt;Datei&amp;lt;/code&amp;gt; / &amp;lt;code&amp;gt;SimGröße&amp;lt;/code&amp;gt; (modified flow regime) is compared to the flow regime of the time series specified under &amp;lt;code&amp;gt;RefGröße&amp;lt;/code&amp;gt; / &amp;lt;code&amp;gt;RefDatei&amp;lt;/code&amp;gt; (natural flow regime). The hydrologic alteration (HA) calculated for each IHA parameter is transformed from the original values ranging between -1 and &amp;amp;infin; to values between 0 and &amp;amp;infin; as described [[rimax33:Aufbau_und_Optimierung_eines_dynamischen_Betriebsregelkonzeptes#Zielfunktion_hydrologische_Ver.C3.A4nderung | here]]. The transformed values are then averaged for each IHA parameter group.&lt;br /&gt;
&lt;br /&gt;
:{| cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot; border=&amp;quot;0&amp;quot; class=&amp;quot;standard stripes&amp;quot;&lt;br /&gt;
|- &lt;br /&gt;
! width=&amp;quot;150&amp;quot; | Parameter !! width=&amp;quot;500&amp;quot; | Beschreibung&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;EvalZeitraum&#039;&#039;&#039;&amp;lt;br/&amp;gt;(optional) || Bestimmt den Zeitraum, für den die Zielfunktion ausgewertet werden soll.&amp;lt;br/&amp;gt;&lt;br /&gt;
Format: &amp;lt;code&amp;gt;dd.mm.yyyy hh:mm&amp;lt;/code&amp;gt;&amp;lt;br/&amp;gt;&lt;br /&gt;
Wenn nicht angegeben, wird der Simulationszeitraum verwendet.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;ZielFkt&#039;&#039;&#039; || Specifies whether the evaluation of IHA parameters should be restricted to a single IHA parameter group. An empty value indicates that the average of all IHA parameter values should be used.&amp;lt;br/&amp;gt;&lt;br /&gt;
Possible values:&lt;br /&gt;
* &amp;lt;code&amp;gt;&amp;amp;nbsp;&amp;lt;/code&amp;gt; (empty)&lt;br /&gt;
* &amp;lt;code&amp;gt;Quantity&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Extremes&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Timing&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Frequency&amp;lt;/code&amp;gt;&lt;br /&gt;
* &amp;lt;code&amp;gt;Rate&amp;lt;/code&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefGröße&#039;&#039;&#039;&amp;lt;br/&amp;gt;(nur bei Referenzreihen und .WEL als Referenzdatei) || Gibt an welche Spalte der .WEL Referenzdatei zum Vergleich herangezogen werden soll.&lt;br /&gt;
|-&lt;br /&gt;
| &#039;&#039;&#039;RefDatei&#039;&#039;&#039; || Der Dateiname der Referenzreihe ([[ZRE-Format|.zre]] oder [[WEL-Format|.wel]])&amp;lt;br/&amp;gt;&amp;lt;span style=&amp;quot;color:red&amp;quot;&amp;gt;&#039;&#039;&#039;Achtung:&#039;&#039;&#039; Die Zeitschrittweite der Referenzreihe muss mit dem Zeitschritt der Simulation übereinstimmen! (siehe Bug 218)&amp;lt;/span&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Literaturangaben==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM.Opt Eingabedateien]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=Urban_Catchments&amp;diff=6772</id>
		<title>Urban Catchments</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=Urban_Catchments&amp;diff=6772"/>
		<updated>2009-12-23T11:15:48Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Abflussbildung */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{HierarchieKopf}}&lt;br /&gt;
&lt;br /&gt;
Der natürlich ablaufende Prozess vom Niederschlag zum Abfluss wird analog zu den natürlichen Einzugsgebieten in die drei Phasen Belastungsbildung, Abflussbildung (bzw. Belastungsaufteilung) und Abflusskonzentration untergliedert. Im Folgenden sind die zugrunde liegenden Berechnungsansätze aufgeführt.&lt;br /&gt;
&lt;br /&gt;
==Belastungsbildung==&lt;br /&gt;
&lt;br /&gt;
Die Belastungsbildung beschreibt die Ermittlung des Gebietsniederschlags für das betrachtete Einzugsgebiet. In BlueM werden Niederschläge über externe Zeitreihen eingelesen, so dass hier keine expliziten Berechnungen erforderlich sind.&lt;br /&gt;
&lt;br /&gt;
==Abflussbildung==&lt;br /&gt;
&lt;br /&gt;
Die Abflussbildung ermittelt aus dem gefallenen Niederschlag den Anteil, der für den Oberflächenabfluss zur Verfügung steht. Der Niederschlag wird in den direkt zum Abfluss gelangenden &amp;quot;effktiven bzw. wirksamen Niederschlag&amp;quot; und die abflussunwirksamen Anteile aufgeteilt. Hierbei handelt es sich um das Wasser, das in Mulden liegen bleibt (Muldenverlust) oder die versiegelten Flächen benetzt (Benetzungsverlust) und letztlich verdunstet oder in den Boden infiltriert. Dementsprechend wird diese Phase auch mit Belastungsaufteilung bezeichnet. Schneefall wird bei urbanen Gebieten nicht berücksichtigt. &lt;br /&gt;
&lt;br /&gt;
Grundsätzlich werden bei der Berechnung die unbefestigten und die befestigten Flächenanteile getrennt betrachtet. Der Anteil der befestigten Flächen an der Gesamtfläche ergibt aus dem Versiegelungsgrad:&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;A_{bef} = VG \cdot A_{ges}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Befestigte Flächenanteile&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bei den befestigten Flächenanteilen berechnet sich der effektive Niederschlag über die Bilanzierung des Niederschlags, der Verdunstung sowie des Oberflächenspeichers. Der Oberflächenspeicher setzt sich aus Mulden und der benetzten Oberfläche zusammen, auf die einzelnen Größen wird weiter unten im Abschnitt &amp;quot;Oberflächenwasservorrat&amp;quot; eingegangen. Hieraus resultiert die folgende Gleichung:&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;Nw(t) = N(t) - VP(t) - \frac{dO}{dt}&amp;lt;/math&amp;gt;&lt;br /&gt;
 &lt;br /&gt;
:mit: &lt;br /&gt;
:NW = abflusswirksamer Niederschlag&lt;br /&gt;
:N = Niederschlag&lt;br /&gt;
:VP = potentielle Verdunstung&lt;br /&gt;
:O = Oberflächenwasservorrat&lt;br /&gt;
&lt;br /&gt;
Der Abflussbeiwert der befestigten Flächen wird grundsätzlich mit &amp;amp;psi; = 1 angesetzt, d.h. es wird davon ausgegangen, dass die resultierende Wassermenge nach Abdeckung der Anfangsverluste für den Oberflächenabfluss zur Verfügung steht. Bei der Festlegung des befestigten Flächenanteils in einem Teileinzugsgebiet ist allerdings zu beachten, dass nicht alle befestigten Flächen tatsächlich in eine Kanalisation entwässern. Erfahrungsgemäß liegt der nicht zum Kanal entwässernde Anteil zwischen 10% und 20%.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Unbefestigte Flächenanteile&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bei den unbefestigten Flächenanteilen wird nicht davon ausgegangen, dass die gesamte resultierende Wassermenge nach Abdeckung der Anfangsverluste für den Oberflächenabfluss zur Verfügung steht. Durch Berücksichtigung eines Abflussbeiwerts &amp;amp;psi; &amp;lt;= 1 wird die Infiltration in den Boden berücksichtigt. &amp;amp;psi; wird entweder durch den Benutzer vorgegeben oder über das SCS-Verfahren berechnet. Für die momentane Belastungsaufteilung ergibt sich somit die folgende Gleichung:&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;Nw(t) = N(t) - VP(t) - I(t) - \frac{dO}{dt}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:mit: &lt;br /&gt;
:NW = abflusswirksamer Niederschlag&lt;br /&gt;
:N = Niederschlag&lt;br /&gt;
:VP = potentielle Verdunstung&lt;br /&gt;
:I = Infiltration in den Bodenraum&lt;br /&gt;
:O = Oberflächenwasservorrat&lt;br /&gt;
&lt;br /&gt;
Im Folgenden werden die einzelnen Verlustanteile beschrieben:&lt;br /&gt;
&lt;br /&gt;
===Verdunstung===&lt;br /&gt;
Es bestehen zwei Optionen für die [[EZG-Datei|Eingabe]] einer potentiellen Verdunstung. Beide Optionen berechnen einen Verdunstungstageswert. Wird mit einem Berechnungsintervall gerechnet, das kleiner als ein Tag ist, wird mittels dem in [[:Bild:Theorie_Abb34.gif|Abbildung 34]] dargestellten Tagesgang die potentielle Verdunstung für jedes Berechnungszeitintervall ermittelt. Ist das Berechnungsintervall &amp;amp;ge; 1 Tag entfällt die Berücksichtigung des Tagesganges.&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb34.gif|thumb|Abbildung 34: Tagesgang der potentiellen Verdunstung als Vielfaches der mittleren Tagesverdunstung]]&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Option 1: Jahresverdunstungssumme&amp;lt;/u&amp;gt;&lt;br /&gt;
[[Bild:Theorie_Abb33.gif|thumb|Abbildung 33: Jahresgang der potentiellen Verdunstung nach {{:Literatur:Brandt_1979}}]]&lt;br /&gt;
Es wird ein normierter Jahresgang  der potentiellen Verdunstung nach {{:Literatur:Brandt_1979|Brandt}} für die Berechnung der potentiellen Verdunstung herangezogen. Aus ausgewerteten Messungen von 20 Stationen, deren Mittelwerte als Histogramm in [[:Bild:Theorie_Abb33.gif|Abbildung 33]] dargestellt sind, wurde folgende Ausgleichsfunktion (gepunktete Linie in [[:Bild:Theorie_Abb33.gif|Abbildung 33]]) ermittelt:&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;VP[\mbox{mm/d}] = \begin{cases}(0.96 + 0.0033 \cdot i) \cdot \sin(\frac{2 \pi}{365})(i - 148) + 1.58, &amp;amp; i &amp;lt;= 300 \\ 2.56 - 1.53 / 65. \cdot (i - 300.), &amp;amp; i &amp;gt; 300 \end{cases}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:mit &lt;br /&gt;
:i = laufender Tag des hydrologischen Jahres&lt;br /&gt;
:i = 1 &amp;amp;rarr; 1. November&lt;br /&gt;
&lt;br /&gt;
Die potentielle Verdunstung nach Brandt bezieht sich auf die {{:Literatur:DVWK_1996|&#039;&#039;&#039;Grasreferenzverdunstung&#039;&#039;&#039;}} und geht von einer Jahresverdunstungshöhe von 654,282 mm aus. Wird eine abweichende Jahresverdunstungshöhe eingegeben, wird der nach Brandt ermittelte Wert entsprechend skaliert.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Option 2: Verdunstungszeitreihe&amp;lt;/u&amp;gt;&lt;br /&gt;
Ist eine Verdunstungszeitreihe gegeben, wird der entsprechende Wert des Zeitschrittes eingelesen. &amp;lt;br/&amp;gt;&lt;br /&gt;
&#039;&#039;Vorsicht:&#039;&#039; Bei einem Simulationszeitschritt &amp;lt; 1d wird der Zeitreihenwert zusätzlich mit einem Tagesgang überprägt! (Bug 1)&lt;br /&gt;
&lt;br /&gt;
===Oberflächenwasservorrat===&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Befestigte Flächenanteile&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Die Oberflächenwasservorratsänderung &amp;lt;code&amp;gt;dO/dt&amp;lt;/code&amp;gt; repräsentiert die Benetzung der Oberfläche sowie die Auffüllung und Entleerung (durch Verdunstung) der Mulden.&lt;br /&gt;
&lt;br /&gt;
Als Benetzungsverlust BV für versiegelte Flächen wird folgender Standardwert angesetzt.&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;code&amp;gt;BV = 0.5 mm&amp;lt;/code&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Der Muldenverlust MV wird durch den Anwender [[ALL-Datei|vorgegeben]]. &lt;br /&gt;
&lt;br /&gt;
Der Muldenverlust stellt den Mittelwert für eine geneigte Oberfläche dar. Da die Mulden jedoch nicht gleichmäßig verteilt sind und erfahrungsgemäß bereits ein Abfluss einsetzt, bevor überall die komplette Muldenauffüllung erreicht ist, wird unterstellt, dass jeweils&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb35.gif|thumb|Abbildung 35: Schema der Modellansätze Benetzungs- und Muldenverluste]]&lt;br /&gt;
&lt;br /&gt;
* 1/3 der versiegelten Fläche einen verminderten Muldenverlust von 1/3 MV &lt;br /&gt;
* 1/3 der versiegelten Fläche den mittleren Muldenverlust von 3/3 MV &lt;br /&gt;
* 1/3 der versiegelten Fläche einen erhöhten Muldenverlust von 5/3 MV &lt;br /&gt;
&lt;br /&gt;
aufweist. Somit kommt es bereits zum Abfluss, wenn der um die Verdunstungsrate verminderte Niederschlag den Benetzungsverlust und 1/3 des Muldenverlustes übersteigt (bei trockener Vorgeschichte). In [[:Bild:Theorie_Abb35.gif|Abbildung 35]] sind die o.g. Annahmen schematisch skizziert.&lt;br /&gt;
&lt;br /&gt;
Die kontinuierliche Bereitstellung der Benetzungs- und Muldenverluste erfolgt über die laufende Bilanzierung dieser Speicher und der Verdunstung.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Unbefestigte Flächenanteile&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Der Oberflächenwasservorrat wird über die Bilanzierung eines Verlustspeichers in Abhängigkeit des gewählten Abflussbildungsansatzes berechnet. Einzelheiten dazu finden sich in den folgenden Abschnitten zur Berechnung der Infiltration.&lt;br /&gt;
&lt;br /&gt;
===Infiltration===&lt;br /&gt;
&lt;br /&gt;
Bei den unbefestigten Flächenanteilen kann die Infiltration in den Boden nicht vernachlässigt werden, da diese das Abflussgeschehen entscheidend prägt. Für die Berechnung wurden zwei Ansätze im Modell implementiert:&lt;br /&gt;
&lt;br /&gt;
# Konstanter Abflussbeiwert &amp;amp;psi;&lt;br /&gt;
# Ereignisspezifischer Abflussbeiwert in Anlehnung an das Verfahren des Soil-Conservation-Service (SCS) &lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Konstanter Abflussbeiwert &amp;amp;psi;&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bei Angabe eines &amp;amp;psi;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt;-Wertes kommt nach Abdeckung der Anfangsverluste (Muldenverlust sowie Verdusntung) der übrige Anteil des Niederschlages im Verhältnis des Abflussbeiwertes &amp;amp;psi;&amp;lt;sub&amp;gt;u&amp;lt;/sub&amp;gt; zum Abfluss und zwar unabhängig von der Vorgeschichte und den Merkmalen des Niederschlages (Höhe, Intensität, Dauer).&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Ereignisspezifischer Abflussbeiwert in Anlehnung an das Verfahren des Soil-Conservation-Service (SCS)&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Bei Angabe eines vom Bodentyp und der Bodennutzung abhängigen CN-Wertes (siehe {{:Literatur:DVWK_1991}}) lässt sich ein vorgeschichtsabhängiger Anfangsverlust sowie eine vorgeschichtsabhängige Beziehung des Abflussbeiwertes von der bis zum betrachteten Zeitpunkt akkumulierten Niederschlagshöhe formulieren (cp. {{:Literatur:Zaiß_1989}}&amp;lt;!-- Im Original TALSIM Dokument steht hier Zaiß 1987!? --&amp;gt;); d.h. der Abflussbeiwert wächst mit zunehmendem Niederschlag im Verlauf des Ereignisses an.&lt;br /&gt;
&lt;br /&gt;
Die Quantifizierung der Vorgeschichte erfolgt über den 21-Tage-Vorregenindex &amp;lt;code&amp;gt;VN&amp;lt;/code&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;V_N = \sum_{j=1}^{21} C(j)^j \cdot h_{N,j}&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:mit&lt;br /&gt;
:&amp;lt;code&amp;gt;h&amp;lt;sub&amp;gt;N,j&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Niederschlagshöhe des j-ten Vortags&lt;br /&gt;
:&amp;lt;code&amp;gt;C(j)&amp;lt;/code&amp;gt; = Faktor, der den Einfluss des j-ten Vortags beschreibt&lt;br /&gt;
&lt;br /&gt;
Der Einfluss der Jahreszeit wird durch einen Jahresgang des Faktors C wiedergegeben.&lt;br /&gt;
&lt;br /&gt;
:&amp;lt;math&amp;gt;C = 0.05 \cdot \sin\left(\frac{2 \pi}{365}\right) (i + 0.75 ) + 0.85&amp;lt;/math&amp;gt;&lt;br /&gt;
&lt;br /&gt;
:mit &lt;br /&gt;
:&amp;lt;code&amp;gt;i&amp;lt;/code&amp;gt; = lfd. Tag des Abflussjahres&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb36.gif|thumb|Abbildung 36: Abhängigkeit des Abflussbeiwertes von der Vorgeschichte]]&lt;br /&gt;
&lt;br /&gt;
Damit schwankt der Wert &amp;lt;code&amp;gt;C&amp;lt;/code&amp;gt; zwischen &amp;lt;code&amp;gt;0,8 &amp;lt; C &amp;lt; 0,9&amp;lt;/code&amp;gt;. Hierdurch wird erreicht, dass bei gleichem Vorregen zu unterschiedlichen Jahreszeiten unterschiedliche Vorregenindizes berechnet und damit eine veränderte Abflussbereitschaft in Rechnung gestellt wird.&lt;br /&gt;
&lt;br /&gt;
In Abhängigkeit von der auf diese Weise quantifizierten Vorgeschichte kann unter Verwendung der gebietsspezifischen und für mittlere Vorfeuchteverhältnisse gültigen CN-Werte ein aktueller Abflussbeiwert berechnet werden. In [[:Bild:Theorie_Abb36.gif|Abbildung 36]] ist für unterschiedliche CN-Werte dargestellt, wie sich der aktuelle Abflussbeiwert in Abhängigkeit von der Vorgeschichte verändert.&lt;br /&gt;
&lt;br /&gt;
[[Bild:Theorie_Abb37.gif|thumb|Abbildung 37: Abhängigkeit des Abflussbeiwertes von der kumulierten Niederschlagssumme]]&lt;br /&gt;
&lt;br /&gt;
Da sich im Verlaufe eines Regenereignisses durch die Durchfeuchtung des Bodens die Abflussbereitschaft eines Einzugsgebiets verändert, wird ebenfalls eine Anpassung des Abflussbeiwertes während eines Ereignisses als Funktion der kumulierten Niederschlagshöhe vorgenommen. In [[:Bild:Theorie_Abb37.gif|Abbildung 37]] ist dieser Zusammenhang für unterschiedliche CN-Werte dargestellt.&lt;br /&gt;
&lt;br /&gt;
==Abflusskonzentration==&lt;br /&gt;
Die Abflusskonzentration bestimmt die Verzögerung des Oberflächenabflusses aus dem Einzugsgebiet. Interflow und Basisabfluss werden bei urbanen Einzugsgebieten nicht berücksichtigt, da die kanalisierten Flächen als Teil des Entwässerungssystems ausschließlcih Oberflächenwasser in der Kanalisation weiterleiten.&lt;br /&gt;
&lt;br /&gt;
Die Berechnung des Oberflächenabflusses erfolgt mit Hilfe einer Parallelspeicherkaskade mit jeweils drei Speichern. Der abflusswirksame Niederschlag des Gesamtgebiets wird durch Mittelwertbildung über die befestigten und unbefestigten Flächen berechnet. Die Aufteilung auf die beiden Speicherkaskaden erfolgt an Hand der Größe des Einzugsgebiets, die Retentionskonstanten der Speicher an Hand der Fließzeit im Einzugsgebiet (siehe {{:Literatur:Ostrowski 1998}}).&lt;br /&gt;
&lt;br /&gt;
==Literaturangaben==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
{{HierarchieFuss}}&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM Theorie]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=FKA-File&amp;diff=6771</id>
		<title>FKA-File</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=FKA-File&amp;diff=6771"/>
		<updated>2009-12-23T11:11:05Z</updated>

		<summary type="html">&lt;p&gt;Heusch: /* Erläuterungen */&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Eingabedateien}}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;big&amp;gt;Urbane Einzugsgebiete&amp;lt;/big&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;siehe auch [[Urbane Einzugsgebiete|Theorie:Urbane Einzugsgebiete]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Datei==&lt;br /&gt;
&amp;lt;bluem&amp;gt;&lt;br /&gt;
*Kanalisierte Flächen (*.FKA)&lt;br /&gt;
*======================&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
*| Bez  | KNG |       EZG       |   N    |   Verdunstung    | PSI | SCS (2)  |             Trockenwetterabfluss                    |&lt;br /&gt;
*|      |     |   A    VG   tf  | Datei  |Kng Sum    Datei  | (1) | CN  VorRg| Einw.  Qh   JGG WGG TGG   Qg  JGG WGG TGG   Qf  JGG |&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
*|  -   | 1-2 |  ha     %   min | Nummer |1/2 mm/a   Nummer |  -  |  -   mm  |   -   l/Ed   -   -   -  l/sha  -   -   -  l/sha  -  |&lt;br /&gt;
*|-&amp;lt;--&amp;gt;-|-&amp;lt;-&amp;gt;-|&amp;lt;----&amp;gt;&amp;lt;----&amp;gt;&amp;lt;--&amp;gt;-|&amp;lt;------&amp;gt;|-+-&amp;lt;----&amp;gt;-&amp;lt;------&amp;gt;|&amp;lt;---&amp;gt;|&amp;lt;---&amp;gt;&amp;lt;---&amp;gt;|-&amp;lt;---&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-|&lt;br /&gt;
 |   A  |  B  |   C     D    E  |    F   | G   H       I    |  J  |  K    L  |   M     N    O   P   Q    R    S   T   U    V    W  |&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
&amp;lt;/bluem&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Erläuterungen==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Bezeichnung:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;A&#039;&#039;&#039;: eindeutige Bezeichnung (muss mit &#039;F&#039; anfangen)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsoptionen:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;B&#039;&#039;&#039;: Berechnungsart [1-2]. Bezieht sich auf die unbefestigten Flächenanteile; die befestigten Flächenanteile werden grundsätzlich mit dem gleichen Ansatz gerechnet. (1) = Abflussbeiswert; (2) = SCS-Verfahren. Infos zu den erforderlichen Parametern und den Berechnungsansätzen weiter unten.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Flächenkenngrößen:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;C&#039;&#039;&#039;: Fläche [ha]&lt;br /&gt;
*&#039;&#039;&#039;D&#039;&#039;&#039;: Versiegelungsgrad [%]&lt;br /&gt;
*&#039;&#039;&#039;E&#039;&#039;&#039;: Längste Fließzeit im Einzugsgebiet [min]. Wird verwendt für die Berechnung der Speicherkonstanten; KSP(1) = 0.25 * (TFA+tf)/60. ); KSP(2) = 5.0*KSP(1)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Niederschlag:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;F&#039;&#039;&#039;: Dateinummer für den Niederschlag (siehe [[TSIM.EXT | *.EXT-Datei]])&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Verdunstung:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;G&#039;&#039;&#039;: Berechnungsart für die Verdunstung (1 = Jahresverdunstungssumme; 2 = Verdunstung aus Zeitreihe/Datei)&lt;br /&gt;
**&#039;&#039;&#039;H&#039;&#039;&#039;: Jahresverdunstungssumme [mm/a] &lt;br /&gt;
*: Einzugeben ist die Summe bezogen auf Grasland, diese wird intern nach {{:Literatur:Brandt_1979|Brandt}} und Haude{{:Literatur:Haude_1954|}}{{:Literatur:Haude_1955|}} mit Ganglinien überprägt und an die jeweilige [[LNZ-Datei|Landnutzung]] der einzelnen Elementarflächen angepasst.&lt;br /&gt;
**&#039;&#039;&#039;I&#039;&#039;&#039;: Dateinummer der zu verwendenden Verdunstungszeitreihe (siehe [[TSIM.EXT | *.EXT-Datei]])&lt;br /&gt;
*:&#039;&#039;es können nur Tageswerte in der Zeitreihe angegeben werden, da die Zeitreihenwerte immer nochmal mit einem Tagesgang überprägt werden! (Bug 1)&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsart 1: Abflussbeiwertverfahren:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;J&#039;&#039;&#039;: Einzugeben ist der Abflussbeiwert &amp;lt;code&amp;gt;(0 &amp;amp;lt; &amp;amp;psi; &amp;amp;le; 1)&amp;lt;/code&amp;gt;, der folgendermaßen definiert ist:&lt;br /&gt;
:&amp;lt;math&amp;gt;\psi = \frac{N_{eff} + E_T + h_v}{N}&amp;lt;/math&amp;gt;&lt;br /&gt;
:mit:&lt;br /&gt;
:&amp;lt;code&amp;gt;N&amp;lt;sub&amp;gt;eff&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Effektiver Niederschlag&lt;br /&gt;
:&amp;lt;code&amp;gt;E&amp;lt;sub&amp;gt;T&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Verdunstung&lt;br /&gt;
:&amp;lt;code&amp;gt;h&amp;lt;sub&amp;gt;v&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Anfangsverlust (Benetzungs- und Muldenverlust)&lt;br /&gt;
:Siehe auch http://de.wikipedia.org/wiki/Abflussbeiwert&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsart 2: SCS-Verfahren:&amp;lt;/u&amp;gt; (Soil-Conservation-Service)&lt;br /&gt;
*&#039;&#039;&#039;K&#039;&#039;&#039;: CN-Wert &amp;lt;code&amp;gt;(0 &amp;amp;lt; CN &amp;amp;le; 100)&amp;lt;/code&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;L&#039;&#039;&#039;: 21-Tage Vorregenhöhe [mm] (&#039;&#039;Wird gleichmäßig auf 21 Tage aufgeteilt&#039;&#039;)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Niederschlag:&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&#039;&#039;&#039;M&#039;&#039;&#039;: Einwohner [-] zur Berechnung des häuslichen Trockenwetterabflusses&lt;br /&gt;
*&#039;&#039;&#039;N&#039;&#039;&#039;: Qh [l/EW*d] - Häuslicher Wasserverbrauch&lt;br /&gt;
*&#039;&#039;&#039;O&#039;&#039;&#039;: Jahresgang [-] des häuslichen Wasserverbrauchs &lt;br /&gt;
*&#039;&#039;&#039;P&#039;&#039;&#039;: Wochengang [-] des häuslichen Wasserverbrauchs&lt;br /&gt;
*&#039;&#039;&#039;Q&#039;&#039;&#039;: Tagesgang [-] des häuslichen Wasserverbrauchs&lt;br /&gt;
*&#039;&#039;&#039;R&#039;&#039;&#039;: Qg [l/s*ha] - Gewerblicher Abfluss&lt;br /&gt;
*&#039;&#039;&#039;S&#039;&#039;&#039;: Jahresgang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;T&#039;&#039;&#039;: Wochengang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;U&#039;&#039;&#039;: Tagesgang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;V&#039;&#039;&#039;: Qf [l/s*ha] - Fremdwasserabfluss&lt;br /&gt;
*&#039;&#039;&#039;W&#039;&#039;&#039;: Jahresgang [-] des Fremdwasserabfluss&lt;br /&gt;
&lt;br /&gt;
==Literaturangaben==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM Eingabedateien]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=FKA-File&amp;diff=6770</id>
		<title>FKA-File</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=FKA-File&amp;diff=6770"/>
		<updated>2009-12-23T11:07:15Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;{{Eingabedateien}}&lt;br /&gt;
&lt;br /&gt;
&amp;lt;big&amp;gt;Urbane Einzugsgebiete&amp;lt;/big&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;siehe auch [[Urbane Einzugsgebiete|Theorie:Urbane Einzugsgebiete]]&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
==Datei==&lt;br /&gt;
&amp;lt;bluem&amp;gt;&lt;br /&gt;
*Kanalisierte Flächen (*.FKA)&lt;br /&gt;
*======================&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
*| Bez  | KNG |       EZG       |   N    |   Verdunstung    | PSI | SCS (2)  |             Trockenwetterabfluss                    |&lt;br /&gt;
*|      |     |   A    VG   tf  | Datei  |Kng Sum    Datei  | (1) | CN  VorRg| Einw.  Qh   JGG WGG TGG   Qg  JGG WGG TGG   Qf  JGG |&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
*|  -   | 1-2 |  ha     %   min | Nummer |1/2 mm/a   Nummer |  -  |  -   mm  |   -   l/Ed   -   -   -  l/sha  -   -   -  l/sha  -  |&lt;br /&gt;
*|-&amp;lt;--&amp;gt;-|-&amp;lt;-&amp;gt;-|&amp;lt;----&amp;gt;&amp;lt;----&amp;gt;&amp;lt;--&amp;gt;-|&amp;lt;------&amp;gt;|-+-&amp;lt;----&amp;gt;-&amp;lt;------&amp;gt;|&amp;lt;---&amp;gt;|&amp;lt;---&amp;gt;&amp;lt;---&amp;gt;|-&amp;lt;---&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;-&amp;gt;-&amp;lt;---&amp;gt;-&amp;lt;-&amp;gt;-|&lt;br /&gt;
 |   A  |  B  |   C     D    E  |    F   | G   H       I    |  J  |  K    L  |   M     N    O   P   Q    R    S   T   U    V    W  |&lt;br /&gt;
*|------|-----|-----------------|--------|------------------|-----|----------|-----------------------------------------------------|&lt;br /&gt;
&amp;lt;/bluem&amp;gt;&lt;br /&gt;
&lt;br /&gt;
==Erläuterungen==&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Bezeichnung:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;A&#039;&#039;&#039;: eindeutige Bezeichnung (muss mit &#039;F&#039; anfangen)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsoptionen:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;B&#039;&#039;&#039;: Berechnungsart [1-2]. Bezieht sich auf die unbefestigten Flächenanteile; die befestigten Flächenanteile werden grundsätzlich mit dem gleichen Ansatz gerechnet. (1) = Abflussbeiswert; (2) = SCS-Verfahren. Infos zu den erforderlichen Parametern und den Berechnungsansätzen weiter unten.&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Flächenkenngrößen:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;C&#039;&#039;&#039;: Fläche [ha]&lt;br /&gt;
*&#039;&#039;&#039;D&#039;&#039;&#039;: Versiegelungsgrad [%]&lt;br /&gt;
*&#039;&#039;&#039;E&#039;&#039;&#039;: Längste Fließzeit im Einzugsgebiet [min]. Wird verwendt für die Berechnung der Speicherkonstanten; KSP(1) = 0.25 * (TFA+tf)/60. ); KSP(2) = 5.0*KSP(1)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Niederschlag:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;F&#039;&#039;&#039;: Dateinummer für den Niederschlag (siehe [[TSIM.EXT | *.EXT-Datei]])&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Verdunstung:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;G&#039;&#039;&#039;: Berechnungsart für die Verdunstung (1 = Jahresverdunstungssumme; 2 = Verdunstung aus Zeitreihe/Datei)&lt;br /&gt;
**&#039;&#039;&#039;H&#039;&#039;&#039;: Jahresverdunstungssumme [mm/a] &lt;br /&gt;
*: Einzugeben ist die Summe bezogen auf Grasland, diese wird intern nach {{:Literatur:Brandt_1979|Brandt}} und Haude{{:Literatur:Haude_1954|}}{{:Literatur:Haude_1955|}} mit Ganglinien überprägt und an die jeweilige [[LNZ-Datei|Landnutzung]] der einzelnen Elementarflächen angepasst.&lt;br /&gt;
**&#039;&#039;&#039;I&#039;&#039;&#039;: Dateinummer der zu verwendenden Verdunstungszeitreihe (siehe [[TSIM.EXT | *.EXT-Datei]])&lt;br /&gt;
*:&#039;&#039;es können nur Tageswerte in der Zeitreihe angegeben werden, da die Zeitreihenwerte immer nochmal mit einem Tagesgang überprägt werden! (Bug 1)&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsart 1: Abflussbeiwertverfahren:&amp;lt;/u&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;J&#039;&#039;&#039;: Abflussbeiwert &amp;lt;code&amp;gt;(0 &amp;amp;lt; &amp;amp;psi; &amp;amp;le; 1)&amp;lt;/code&amp;gt;&lt;br /&gt;
:&amp;lt;math&amp;gt;\psi = \frac{N_{eff} + E_T + h_v}{N}&amp;lt;/math&amp;gt;&lt;br /&gt;
:mit:&lt;br /&gt;
:&amp;lt;code&amp;gt;N&amp;lt;sub&amp;gt;eff&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Effektiver Niederschlag&lt;br /&gt;
:&amp;lt;code&amp;gt;E&amp;lt;sub&amp;gt;T&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Verdunstung&lt;br /&gt;
:&amp;lt;code&amp;gt;h&amp;lt;sub&amp;gt;v&amp;lt;/sub&amp;gt;&amp;lt;/code&amp;gt; = Anfangsverlust (Benetzungs- und Muldenverlust)&lt;br /&gt;
:Siehe auch http://de.wikipedia.org/wiki/Abflussbeiwert&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Berechnungsart 2: SCS-Verfahren:&amp;lt;/u&amp;gt; (Soil-Conservation-Service)&lt;br /&gt;
*&#039;&#039;&#039;K&#039;&#039;&#039;: CN-Wert &amp;lt;code&amp;gt;(0 &amp;amp;lt; CN &amp;amp;le; 100)&amp;lt;/code&amp;gt;&lt;br /&gt;
*&#039;&#039;&#039;L&#039;&#039;&#039;: 21-Tage Vorregenhöhe [mm] (&#039;&#039;Wird gleichmäßig auf 21 Tage aufgeteilt&#039;&#039;)&lt;br /&gt;
&lt;br /&gt;
&amp;lt;u&amp;gt;Niederschlag:&amp;lt;/u&amp;gt;&lt;br /&gt;
&lt;br /&gt;
*&#039;&#039;&#039;M&#039;&#039;&#039;: Einwohner [-] zur Berechnung des häuslichen Trockenwetterabflusses&lt;br /&gt;
*&#039;&#039;&#039;N&#039;&#039;&#039;: Qh [l/EW*d] - Häuslicher Wasserverbrauch&lt;br /&gt;
*&#039;&#039;&#039;O&#039;&#039;&#039;: Jahresgang [-] des häuslichen Wasserverbrauchs &lt;br /&gt;
*&#039;&#039;&#039;P&#039;&#039;&#039;: Wochengang [-] des häuslichen Wasserverbrauchs&lt;br /&gt;
*&#039;&#039;&#039;Q&#039;&#039;&#039;: Tagesgang [-] des häuslichen Wasserverbrauchs&lt;br /&gt;
*&#039;&#039;&#039;R&#039;&#039;&#039;: Qg [l/s*ha] - Gewerblicher Abfluss&lt;br /&gt;
*&#039;&#039;&#039;S&#039;&#039;&#039;: Jahresgang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;T&#039;&#039;&#039;: Wochengang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;U&#039;&#039;&#039;: Tagesgang [-] des gewerblichen Abfluss&lt;br /&gt;
*&#039;&#039;&#039;V&#039;&#039;&#039;: Qf [l/s*ha] - Fremdwasserabfluss&lt;br /&gt;
*&#039;&#039;&#039;W&#039;&#039;&#039;: Jahresgang [-] des Fremdwasserabfluss&lt;br /&gt;
&lt;br /&gt;
==Literaturangaben==&lt;br /&gt;
&amp;lt;references/&amp;gt;&lt;br /&gt;
&lt;br /&gt;
[[Kategorie:BlueM Eingabedateien]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6740</id>
		<title>TXT-Format</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6740"/>
		<updated>2009-10-27T12:37:10Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [[SWMM]]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|SWMM_txtFormat.pdf|SWMM-Formatbeschreibung}}. Die erste Zeile der Datei muss mit dem Schlüsselwort &amp;quot;SWMM5&amp;quot; beginnen.&lt;br /&gt;
&lt;br /&gt;
Beispiel (nur Abfluss):&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
SWMM5 Interface File&lt;br /&gt;
RTC-Demonstrator , Regenbelastung Wupperverband , &lt;br /&gt;
 60 - reporting time step in sec&lt;br /&gt;
 1    - number of constituents as listed below:&lt;br /&gt;
FLOW LPS&lt;br /&gt;
 5    - number of nodes as listed below:&lt;br /&gt;
S101&lt;br /&gt;
S201&lt;br /&gt;
S401&lt;br /&gt;
S203&lt;br /&gt;
S602&lt;br /&gt;
Node          Year Mon Day Hr  Min Sec         FLOW&lt;br /&gt;
S101          2001 6   10  0   0   0          0.000&lt;br /&gt;
S201          2001 6   10  0   0   0          0.000&lt;br /&gt;
S401          2001 6   10  0   0   0          0.000&lt;br /&gt;
S203          2001 6   10  0   0   0          0.000&lt;br /&gt;
S602          2001 6   10  0   0   0          0.000&lt;br /&gt;
S101          2001 6   10  0   1   0          1.960&lt;br /&gt;
S201          2001 6   10  0   1   0          0.420&lt;br /&gt;
S401          2001 6   10  0   1   0          1.400&lt;br /&gt;
S203          2001 6   10  0   1   0          0.560&lt;br /&gt;
S602          2001 6   10  0   1   0          4.900&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Beispiel (Abfluss und Konzentrationsdaten):&lt;br /&gt;
&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
SWMM5 Interface File&lt;br /&gt;
RTC-Demo &lt;br /&gt;
 60 - reporting time step in sec&lt;br /&gt;
 2    - number of constituents as listed below:&lt;br /&gt;
FLOW LPS&lt;br /&gt;
CSB MG/L&lt;br /&gt;
 2    - number of nodes as listed below:&lt;br /&gt;
S201&lt;br /&gt;
S101&lt;br /&gt;
Node          Year Mon Day Hr  Min Sec         FLOW  CSB      &lt;br /&gt;
S201          2008 4   1   12  0   0          0.000    50.0000&lt;br /&gt;
S101          2008 4   1   12  0   0          0.000   100.0000&lt;br /&gt;
S201          2008 4   1   12  1   0         15.625    50.0000&lt;br /&gt;
S101          2008 4   1   12  1   0         15.625   100.0000&lt;br /&gt;
S201          2008 4   1   12  2   0         15.625    50.0000&lt;br /&gt;
S101          2008 4   1   12  2   0         15.625   100.0000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6739</id>
		<title>TXT-Format</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6739"/>
		<updated>2009-10-27T11:55:40Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [[SWMM]]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|SWMM_txtFormat.pdf|SWMM-Formatbeschreibung}}. Die erste Zeile der Datei muss mit dem Schlüsselwort &amp;quot;SWMM5&amp;quot; beginnen.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
SWMM5 Interface File&lt;br /&gt;
RTC-Demonstrator , Regenbelastung Wupperverband , &lt;br /&gt;
 60 - reporting time step in sec&lt;br /&gt;
 1    - number of constituents as listed below:&lt;br /&gt;
FLOW LPS&lt;br /&gt;
 5    - number of nodes as listed below:&lt;br /&gt;
S101&lt;br /&gt;
S201&lt;br /&gt;
S401&lt;br /&gt;
S203&lt;br /&gt;
S602&lt;br /&gt;
Node          Year Mon Day Hr  Min Sec         FLOW&lt;br /&gt;
S101          2001 6   10  0   0   0          0.000&lt;br /&gt;
S201          2001 6   10  0   0   0          0.000&lt;br /&gt;
S401          2001 6   10  0   0   0          0.000&lt;br /&gt;
S203          2001 6   10  0   0   0          0.000&lt;br /&gt;
S602          2001 6   10  0   0   0          0.000&lt;br /&gt;
S101          2001 6   10  0   1   0          1.960&lt;br /&gt;
S201          2001 6   10  0   1   0          0.420&lt;br /&gt;
S401          2001 6   10  0   1   0          1.400&lt;br /&gt;
S203          2001 6   10  0   1   0          0.560&lt;br /&gt;
S602          2001 6   10  0   1   0          4.900&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6738</id>
		<title>TXT-Format</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6738"/>
		<updated>2009-10-27T11:53:31Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [[SWMM]]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|SWMM_txtFormat.pdf|SWMM-Formatbeschreibung}}. Die erste Zeile der Datei muss mit dem Schlüsselwort &amp;quot;SWMM&amp;quot; beginnen.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
SWMM5 Interface File&lt;br /&gt;
RTC-Demonstrator , Regenbelastung Wupperverband , &lt;br /&gt;
 60 - reporting time step in sec&lt;br /&gt;
 1    - number of constituents as listed below:&lt;br /&gt;
FLOW LPS&lt;br /&gt;
 5    - number of nodes as listed below:&lt;br /&gt;
S101&lt;br /&gt;
S201&lt;br /&gt;
S401&lt;br /&gt;
S203&lt;br /&gt;
S602&lt;br /&gt;
Node          Year Mon Day Hr  Min Sec         FLOW&lt;br /&gt;
S101          2001 6   10  0   0   0          0.000&lt;br /&gt;
S201          2001 6   10  0   0   0          0.000&lt;br /&gt;
S401          2001 6   10  0   0   0          0.000&lt;br /&gt;
S203          2001 6   10  0   0   0          0.000&lt;br /&gt;
S602          2001 6   10  0   0   0          0.000&lt;br /&gt;
S101          2001 6   10  0   1   0          1.960&lt;br /&gt;
S201          2001 6   10  0   1   0          0.420&lt;br /&gt;
S401          2001 6   10  0   1   0          1.400&lt;br /&gt;
S203          2001 6   10  0   1   0          0.560&lt;br /&gt;
S602          2001 6   10  0   1   0          4.900&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6736</id>
		<title>TXT-Format</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=TXT-Format&amp;diff=6736"/>
		<updated>2009-10-27T09:01:16Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Neu angelegt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [[SWMM]]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|SWMM_txtFormat.pdf|SWMM-Formatbeschreibung}}.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
SWMM5 Interface File&lt;br /&gt;
RTC-Demonstrator , Regenbelastung Wupperverband , &lt;br /&gt;
 60 - reporting time step in sec&lt;br /&gt;
 1    - number of constituents as listed below:&lt;br /&gt;
FLOW LPS&lt;br /&gt;
 5    - number of nodes as listed below:&lt;br /&gt;
S101&lt;br /&gt;
S201&lt;br /&gt;
S401&lt;br /&gt;
S203&lt;br /&gt;
S602&lt;br /&gt;
Node          Year Mon Day Hr  Min Sec         FLOW&lt;br /&gt;
S101          2001 6   10  0   0   0          0.000&lt;br /&gt;
S201          2001 6   10  0   0   0          0.000&lt;br /&gt;
S401          2001 6   10  0   0   0          0.000&lt;br /&gt;
S203          2001 6   10  0   0   0          0.000&lt;br /&gt;
S602          2001 6   10  0   0   0          0.000&lt;br /&gt;
S101          2001 6   10  0   1   0          1.960&lt;br /&gt;
S201          2001 6   10  0   1   0          0.420&lt;br /&gt;
S401          2001 6   10  0   1   0          1.400&lt;br /&gt;
S203          2001 6   10  0   1   0          0.560&lt;br /&gt;
S602          2001 6   10  0   1   0          4.900&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=BlueM.Wave&amp;diff=6735</id>
		<title>BlueM.Wave</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=BlueM.Wave&amp;diff=6735"/>
		<updated>2009-10-27T08:55:47Z</updated>

		<summary type="html">&lt;p&gt;Heusch: TXT-Format (SWMM Routing Interface File) hinzugefügt&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;__NOTOC__&lt;br /&gt;
{{Wave_nav}}&lt;br /&gt;
[[Bild:Wave_screenshot.png|thumb|Screenshot]]&lt;br /&gt;
[[Bild:Monatsauswertung.png|thumb|Analysis function months evaluation]]&lt;br /&gt;
[[Bild:Doppelsummenanalyse.png|thumb|Analysis function double sum analysis]]&lt;br /&gt;
[[Bild:Wave_Statistik.png|thumb|Statistical analysis function]]&lt;br /&gt;
==Description==&lt;br /&gt;
Wave is a tool for importing, exporting, analyzing and displaying time series.&lt;br /&gt;
&lt;br /&gt;
==Features==&lt;br /&gt;
* &#039;&#039;&#039;Import time series:&#039;&#039;&#039;&lt;br /&gt;
** [[WEL-Format | WEL]] ([[WEL-Format (BlueM)|BlueM]] and [[WEL-Format (Hystem-Extran)|Hystem-Extran]])&lt;br /&gt;
** [[ZRE-Format | ZRE]]&lt;br /&gt;
** [[ASC-Format | ASC]] &lt;br /&gt;
** [[SMB-Format | SMB]] &lt;br /&gt;
** [[REG-Format | REG]] ([[SMUSI REG-Format|SMUSI]] and [[Hystem-Extran REG-Format|Hystem-Extran]])&lt;br /&gt;
** OUT ([[SWMM]] binary result files)&lt;br /&gt;
** [[TXT-Format | TXT]] ([[SWMM]] Routing interface files)&lt;br /&gt;
** and generic text files (e.g. [[CSV-Format | CSV]])&lt;br /&gt;
* &#039;&#039;&#039;Input time series:&#039;&#039;&#039; manual input, or copy &amp;amp; paste from Excel&lt;br /&gt;
* &#039;&#039;&#039;Display time series&#039;&#039;&#039; in a [http://www.steema.com/products/teechart/overview.html TeeChart] diagram with any number of axes, etc.&lt;br /&gt;
** When importing time series, series are automatically assigned to different axes depending on their unit. &lt;br /&gt;
* &#039;&#039;&#039;Save diagrams&#039;&#039;&#039; (TEN-File)&lt;br /&gt;
* &#039;&#039;&#039;Drag&amp;amp;Drop&#039;&#039;&#039; files onto the form and &amp;quot;Open with ...&amp;quot;, or double-click on file (if file extension is associated with Wave.exe)&lt;br /&gt;
* &#039;&#039;&#039;Time series overview&#039;&#039;&#039; for navigating through long time series&lt;br /&gt;
* &#039;&#039;&#039;API&#039;&#039;&#039;, used by [[BlueM.Opt]] and [[BlueM.Win]].&lt;br /&gt;
* &#039;&#039;&#039;Export time series:&#039;&#039;&#039;&lt;br /&gt;
** [[ZRE-Format | ZRE]]&lt;br /&gt;
** [[SMUSI REG-Format | SMUSI REG]]&lt;br /&gt;
** [[SWMM]] DAT&lt;br /&gt;
** &amp;lt;del&amp;gt;[[WEL-Format | WEL]]&amp;lt;/del&amp;gt; (not yet - Bug 318)&lt;br /&gt;
** CSV and XLS made available by TeeChart&lt;br /&gt;
* &#039;&#039;&#039;Crop time series&#039;&#039;&#039;&lt;br /&gt;
* &#039;&#039;&#039;Time series analysis:&#039;&#039;&#039;&lt;br /&gt;
** [[Wave:Monatsauswertung|Monthly statistics]]&lt;br /&gt;
** [[Wave:Doppelsummenanalyse|Double mass curve]]&lt;br /&gt;
** [[Wave:GoodnessOfFit|Goodness of Fit]] (volume error, sum of squares error, Nash-Sutcliffe efficiency, etc.)&lt;br /&gt;
** [[Wave:Statistik|Statistics]]&lt;br /&gt;
** [[Wave:Gegenueberstellung|Plot two time series against each other]]&lt;br /&gt;
&lt;br /&gt;
==Notes==&lt;br /&gt;
===Importing time series===&lt;br /&gt;
* WEL and ZRE files have to adhere to the file format: see [[WEL-Format|WEL]], [[ZRE-Format|ZRE]].&lt;br /&gt;
* &#039;&#039;&#039;Number format:&#039;&#039;&#039; &lt;br /&gt;
** Decimal point should be represented by a dot (&amp;lt;code&amp;gt;.&amp;lt;/code&amp;gt;) (Bug 351)&lt;br /&gt;
** &amp;quot;NaN&amp;quot;, &amp;quot;Infinity&amp;quot; and &amp;quot;-Infinity&amp;quot; in import files are recognized and accepted.&amp;lt;br/&amp;gt; Unreadable values are converted to NaN.&amp;lt;br/&amp;gt;Values of NaN or Infinity are removed before displaying or performing analysis functions.&lt;br /&gt;
* &#039;&#039;&#039;Date format&#039;&#039;&#039;&lt;br /&gt;
:{| border=&amp;quot;0&amp;quot; cellpadding=&amp;quot;5&amp;quot; cellspacing=&amp;quot;0&amp;quot;&lt;br /&gt;
| TXT, CSV, ASC and WEL || &amp;amp;rarr; || &amp;lt;code&amp;gt;DD.MM.YYYY HH:MM&amp;lt;/code&amp;gt;&lt;br /&gt;
|-&lt;br /&gt;
| ZRE || &amp;amp;rarr; || &amp;lt;code&amp;gt;YYYYMMDD HH:MM&amp;lt;/code&amp;gt;&lt;br /&gt;
|}&lt;br /&gt;
&lt;br /&gt;
==Development==&lt;br /&gt;
* [[Wave:Code|Code documentation]]&lt;br /&gt;
* [http://130.83.196.154/svn/Wave/trunk/WAVE_RELEASE-NOTES.txt RELEASE-NOTES]&lt;br /&gt;
* [http://bugs.bluemodel.org/buglist.cgi?bug_status=UNCONFIRMED&amp;amp;bug_status=NEW&amp;amp;bug_status=ASSIGNED&amp;amp;bug_status=REOPENED&amp;amp;content=&amp;amp;product=Wave&amp;amp;query_format=specific&amp;amp;order=bug_severity%2Cpriority%20ASC&amp;amp;query_based_on= Bugzilla:Wave]&lt;br /&gt;
&lt;br /&gt;
[[Category:Wave]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=WEL-Format_(Hystem-Extran)&amp;diff=6734</id>
		<title>WEL-Format (Hystem-Extran)</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=WEL-Format_(Hystem-Extran)&amp;diff=6734"/>
		<updated>2009-10-27T08:17:40Z</updated>

		<summary type="html">&lt;p&gt;Heusch: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [http://www.itwh.de/S_extinfo.htm Hystem-Extran]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|HysExt_welFormat.pdf|Hystem-Extran-Formatbeschreibung}}. Die Einheit ist mit m3/s festgelegt.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Regenbelastung                                                                 &lt;br /&gt;
Musterstadt                                                                  &lt;br /&gt;
  11 42008    18 0 0  14 42008     1 5 0&lt;br /&gt;
HYSTEM BLOCK           32&lt;br /&gt;
17*21     17O8      17*37     17*43     17K1      17D19     17H17     17K8      &lt;br /&gt;
36F7      17U5      17P28     17S5      17X19     17T15     17T31     17Z8      &lt;br /&gt;
36R36     36M41     17W226    17X34     17W58     17Y31     17Z21     17Z12     &lt;br /&gt;
17Z20     17Z6      36*13     36*33     36B15     38*72     38E2      38P44     &lt;br /&gt;
  11 42008    18 0 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  11 42008    2017 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
.&lt;br /&gt;
.&lt;br /&gt;
.&lt;br /&gt;
  14 42008     1 5 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
********************&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Der Datensatz muss mit einem Block abschließen, bei dem alle Daten genullt sind und dem eine Zeile mit 20 * vorsteht (siehe Beispiel).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
	<entry>
		<id>https://wiki.bluemodel.org/index.php?title=WEL-Format_(Hystem-Extran)&amp;diff=6733</id>
		<title>WEL-Format (Hystem-Extran)</title>
		<link rel="alternate" type="text/html" href="https://wiki.bluemodel.org/index.php?title=WEL-Format_(Hystem-Extran)&amp;diff=6733"/>
		<updated>2009-10-27T07:48:23Z</updated>

		<summary type="html">&lt;p&gt;Heusch: Link zur pdf-Datei geändert&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Format für Zuflussdaten in [http://www.itwh.de/S_extinfo.htm Hystem-Extran]. &lt;br /&gt;
&lt;br /&gt;
Eine Beschreibung des Formats findet sich in der {{file|pdf|HysExt_welFormat.pdf|Hystem-Extran-Formatbeschreibung}}.&lt;br /&gt;
&lt;br /&gt;
Beispiel:&lt;br /&gt;
&amp;lt;pre&amp;gt;&lt;br /&gt;
Regenbelastung                                                                 &lt;br /&gt;
Musterstadt                                                                  &lt;br /&gt;
  11 42008    18 0 0  14 42008     1 5 0&lt;br /&gt;
HYSTEM BLOCK           32&lt;br /&gt;
17*21     17O8      17*37     17*43     17K1      17D19     17H17     17K8      &lt;br /&gt;
36F7      17U5      17P28     17S5      17X19     17T15     17T31     17Z8      &lt;br /&gt;
36R36     36M41     17W226    17X34     17W58     17Y31     17Z21     17Z12     &lt;br /&gt;
17Z20     17Z6      36*13     36*33     36B15     38*72     38E2      38P44     &lt;br /&gt;
  11 42008    18 0 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  11 42008    2017 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
.&lt;br /&gt;
.&lt;br /&gt;
.&lt;br /&gt;
  14 42008     1 5 0&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
********************&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000  0.000000&lt;br /&gt;
&amp;lt;/pre&amp;gt;&lt;br /&gt;
&lt;br /&gt;
Der Datensatz muss mit einem Block abschließen, bei dem alle Daten genullt sind und dem eine Zeile mit 20 * vorsteht (siehe Beispiel).&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
[[Category:Zeitreihenformate]]&lt;/div&gt;</summary>
		<author><name>Heusch</name></author>
	</entry>
</feed>