VER-File

From BlueM
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

BlueM_icon.png BlueM.Sim | Downloads | Application | Theory | Development

Input files · ALL SYS · FKT KTR · EXT JGG WGG TGG · TAL HYA TRS EIN URB VER RUE BEK EZG FKA · BOA BOD LNZ EFL · DIF


Branching points

also refer to Theory: Branching point

File

Versionen:

*Verzweigungen (*.VER)
*=====================
*
*|------------|-------------------------------|--------------|-----------------------|
*| Bez.   Kng |       N a e h e r u n g       | 3 Kennlinie  |  Regeln und Steuern   |
*|      |     | 1 Schwellenw.| 2 proz.Aufteilg|              | KTR                   |
*|      |     | Qswell Trenn |(gibt nach Qab1)|  Qzu    Qab  | ID  Faktor JGG WGG TGG|
*|------------|-------------------------------|--------------|-----------------------|
*|  -   | 1-3 |  m3/s   -    |       %        |  m3/s  m3/s  |  -    -     -   -   - |
*|-<-->-|-<->-|-<----><---->-|-<------------>-|-<----><---->-|-<->-<---->-<->-<->-<->|
*|   A  |  B  |   C      D   |       E        |    F     G   |  H    I     J   K   L |
 | V001 |  1  |  0.03    1   |                |              | y01                   |
 | V002 |  2  |              |      50        |              | y01                   |
 | V003 |  3  |              |                |      0     0 | y01                   |
 |      |     |              |                |   0.03 0.030 |                       |
 |      |     |              |                |   0.04 0.032 |                       |
 |      |     |              |                |   0.10 0.033 |                       |
*|------------|-------------------------------|--------------|-----------------------|

Explanations

  • A: ID of the branching point(must start with 'V'!)
  • B: Calculation type of the distribution:
    1 = threshold value with the option to define the selectivity
    2 = percentage distribution
    3 = characteristic curve

Calculation type 1: threshold value

  • C: threshold value that defines as of which critical inflow Qkrit the 2. outflow is added
  • D: the selectivity for the threshold value [1.0 – ∞]

Calculation type 2: percentage distribution

  • E: Independent of the inflow a constant distribution in two outflows Qab1 and Qab2 according to a certain percentage ratio will be used. If 100% the 1. outflow will contain the entire inflow. [0 – 100%]

Calculation type 3: characteristic curve

  • F, G: A dependency between outflow Qab1 and inflow resulting out of hydraulic calculations or operation standards is set as a polygon course. The second outflow Qab2 is calculated as the remaining value of (inflow - Qab1).

Regulation and steering:

  • H: ID of the control function, out of which the scaling factor will be derived (refer to KTR-File)
  • I: additional factor(if not supplied or 0, this factor will be set to 1!)
  • J, K, L: number of the annual/weekly/daily pattern to be utilized

Depending on the calculation type the scaling factor is applied differently:

  1. (threshold value): the threshold value is scaled with the factor
  2. (percentage distribution): the given percentage is scaled with the factor (however it will remain between 0 and 100)
  3. (characteristic curve): All Qab-values of the characteristic curve are scaled with the factor